Lubi LCR 10 50 Hz technical data booklet, hosted by E Water Treatment India

Lubi

The Lubi LCR 10 booklet tabulates 16 vertical multistage centrifugal pump models (LCR 10/1 to 10/22) at 2900 rpm, 7-12 m³/h, with 10 to 213 m head and 0.37-7.5 kW motors.

On this page

Overview

This 4-page Lubi data booklet holds the performance chart, performance curves and dimension and weight tables for the LCR 10 series (stainless steel, vertical, multistage centrifugal) and its LCRI and LCRN 10 variants. The pumps are given for 50 Hz, 2900 rpm, with curves per ISO 9906:2012 grade 3B. The copy hosted on the distributor's site (E Water Treatment India) is the manufacturer's document.

The performance table lists sixteen models by stage count: LCR 10/1, 10/2, 10/3, 10/4, 10/5, 10/6, 10/7, 10/8, 10/9, 10/10, 10/12, 10/14, 10/16, 10/18, 10/20 and 10/22. Each row gives rated motor power (HP and kW) and head in metres at 7, 8, 9, 10, 11 and 12 m³/h. For example the LCR 10/1 delivers 10 m at 7 m³/h and 6 m at 12 m³/h; the LCR 10/22 delivers 213 m at 7 m³/h and 148 m at 12 m³/h.

The dimension and weight table gives D1, D2, D3 dimensions, DIN flange dimension, net and gross weight and gross volume for each model. Net weight is 34 kg for the LCR 10/1 and 105 kg for the LCR 10/22. The connection is drawn as DIN-JIS flange, PN 16-25, DN 40, with G½ auxiliary ports shown.

Rated motor power is not the same as measured electrical consumption at the selected flow; the booklet does not select a duty point and only pairs flow and head for model comparison. Material variants are not duplicated into separate model rows.

Key points

  1. 16 models: LCR 10/1 to 10/22, with 1 to 22 stages.
  2. Flow points are 7, 8, 9, 10, 11 and 12 m³/h (116.7-200 l/min); speed 2900 rpm, 50 Hz.
  3. LCR 10/1: motor 0.37 kW (0.5 HP), head 10 m (7 m³/h) to 6 m (12 m³/h).
  4. LCR 10/10: motor 4 kW (5.5 HP), head 97 m (7 m³/h) to 67 m (12 m³/h).
  5. LCR 10/22: motor 7.5 kW (10 HP), head 213 m (7 m³/h) to 148 m (12 m³/h).
  6. Net weight is 34 kg (10/1) to 105 kg (10/22); gross weight 48-139 kg.
  7. Flange is DIN-JIS PN 16-25, DN 40; curves follow ISO 9906:2012 grade 3B.

Using it in design

  • For cooling water and glycol loops, select the pump with the smallest stage count that covers the head needed at design flow (pipe, exchanger and valve losses combined).
  • Do not use rated motor power as measured consumption; take electrical power at the operating point from the curve or the manufacturer.
  • Keep the selection inside the 7-12 m³/h range; the booklet covers only this range.
  • Carry net and gross weights into handling and floor load calculations and dimension D1 into pump room layout.

Who should read it

Mechanical designers selecting small-flow vertical multistage pumps for cooling water and glycol circuits.

Document contents

  1. LCR 10 performance chart
  2. LCR 10 dimensions and weights
  3. LCR 10 performance curves
  4. LCRI and LCRN 10 performance chart
  5. LCRI and LCRN 10 dimensions and weights

Publication details

Authors
Lubi
Publisher
Lubi
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Lubi Lubi LCR 10 50 Hz technical data booklet, hosted by E Water Treatment India. Lubi. https://ewatertreatmentindia.com/upload/product_information/DataBookletLCR50LubiLCR10wFiltrav7.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.