Mammoth APAC Data Centre Solutions: CLOUD-MIRAGE In-Row Precision Air Conditioner

Original title Mammoth APAC Data Centre Solutions: CLOUD-MIRAGE

Mammoth

The Mammoth APAC catalogue presents CLOUD-AIR (CRAC, 7-200 kW), CLOUD-MIRAGE (in-row) and CLOUD-ORBIT (rack-mounted, 4 kW 5U and 8 kW 8U) precision cooling, with DX and chilled-water operating points for MIRAGE.

On this page

Overview

The catalogue presents data-centre solutions from Mammoth, which states it was founded in Minneapolis in 1935, in three product lines. CLOUD-AIR is a CRAC unit giving high-precision temperature and humidity control for small to large data rooms; it comes in air-cooled, water-cooled and chilled-water types covering 7-200 kW. Listed features are scroll compressor, R410A, EC centrifugal fan, electronic expansion valve, 7-inch touch screen and CAN-network group control of up to 32 units.

CLOUD-MIRAGE is an in-row precision air conditioner for medium and high-density data centres: full inverter, high sensible heat ratio (avoiding the loss of repeated dehumidifying and humidifying), R410A, EC fan with fan-wall air supply, PTC electric heating and wet-film humidification at almost zero power (stated to reduce PUE). The outdoor condenser fan has stepless speed control; a water-spray energy-saving module and a refrigerant pump (fluorine pump) module are optional. In the heat-pipe series water does not enter the data centre. The water-cooled condition is 30/35 °C inlet/outlet water; supply is 380 V 3N 50 Hz.

CLOUD-ORBIT rack-mounted units embed in the rack for micro data centres, edge computing and base-station rooms: sizes such as 5U (4 kW) and 8U (8 kW), EC fan, DC inverter compressor, a 24/7 uninterrupted design with up to 10 years design life, dry contact and RS485 interfaces, and top or side air outlet options. For MIRAGE the catalogue tabulates operating points for five DX models and two chilled-water models; there is no net sensible capacity label.

Key points

  1. CLOUD-AIR CRAC capacity 7-200 kW; air-cooled, water-cooled and chilled-water types.
  2. CLOUD-MIRAGE: full-inverter in-row unit; high sensible heat ratio, EC fan, R410A.
  3. Group control of up to 32 units on CAN network; 7-inch touch screen.
  4. MIRAGE operating points tabulated for 5 DX and 2 chilled-water models; no net sensible capacity label.
  5. Water-cooled condition 30/35 °C water; supply 380 V 3N 50 Hz; CRAC rating basis is 24 °C dry-bulb, 17 °C wet-bulb return air and 35 °C outdoor dry bulb.
  6. Wet-film humidification at almost zero power, stated to reduce PUE.
  7. CLOUD-ORBIT: 5U 4 kW and 8U 8 kW rack-mounted units; up to 10 years design life.

Using it in design

  • Read in-row unit capacity at the tabulated operating point; with no net sensible capacity label, deduct fan heat separately.
  • In medium and high-density halls assess the high sensible heat ratio and fan-wall supply together with contained-aisle design.
  • On the chilled-water model compare the heat-pipe option where water stays out of the data centre, and the fluorine-pump module, as free-cooling options.
  • For micro data centres and base stations match the ORBIT 4 and 8 kW classes to rack heat load.
  • Use group control of up to 32 units in the redundancy and rotation concept.

Who should read it

Mechanical designers selecting in-row and rack-mounted precision cooling and planners of micro data centres.

Document contents

  1. About Mammoth
  2. CLOUD-AIR CRAC unit
  3. CLOUD-MIRAGE in-row precision air conditioner
  4. CLOUD-ORBIT rack-mounted precision air conditioner

Publication details

Authors
Mammoth
Publisher
Mammoth
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Mammoth Mammoth APAC Data Centre Solutions: CLOUD-MIRAGE. Mammoth. https://mammothapac.com/uploads/catalogs/1768120488.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.