Mammoth High Efficiency Water Cooled Screw Chiller, High Efficiency Technical Specification sheet 2-1

Mammoth

The Mammoth MCRH high-efficiency water-cooled screw chiller page lists single- and dual-compressor model rows at 7°C load-side leaving water and 30°C condenser entering water.

On this page

Overview

Mammoth's product page presents the MCRH series of water-cooled screw chillers with single-compressor and dual-compressor model rows. The technical specification table states load-side outlet water of 7°C and condenser inlet water of 30°C.

Shipping and operating weights are kept separate. The correct column must therefore be chosen for structural load and handling calculations, and capacity values apply only at the stated water conditions.

Key points

  1. MCRH screw water chillers have single- and dual-compressor model rows.
  2. Load-side outlet water is 7°C.
  3. Condenser inlet water is 30°C.
  4. Shipping and operating weights are in separate columns.

Using it in design

  • Do not use capacity directly for a design that departs from 7°C load water and 30°C condenser water.
  • Use operating weight for structural calculation and shipping weight for handling plans.
  • Compare single- and dual-compressor rows for redundancy and part-load needs.

Who should read it

Data-centre mechanical designers selecting water-cooled screw chillers.

Publication details

Authors
Mammoth
Publisher
Mammoth
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only. Original publisher HTTP URL retained as a bibliographic link. Its HTTPS counterpart could not be verified on 2026-11-16; no content was downloaded or redistributed.

Citation

Mammoth Mammoth High Efficiency Water Cooled Screw Chiller, High Efficiency Technical Specification sheet 2-1. Mammoth. http://m.mammoth-hvac.com/screw-chiller/water-cooled-screw-chiller/high-efficiency-water-cooled-screw-chiller.html

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.