AI for Automating Data Center Operations: Model Explainability in the Data Centre Context Using Shapley Additive Explanations (SHAP)

Electronics (MDPI AG) · Yibrah Gebreyesus, Damian Dalton et al.

A 2024 Electronics (MDPI) paper applies SHAP explainability to predictive-maintenance models using real data from the ENEA CRESCO6 HPC cluster in Italy, including how feature importance changes over time.

On this page

Overview

The paper addresses the interpretability and transparency problem of AI and machine-learning models used in data-centre operations. The proposed method assigns each input feature a SHAP value that quantifies its contribution to the model output, so an operator can see why a model gave a particular prediction and act proactively.

The approach is validated on predictive-maintenance models with an actual dataset from the ENEA CRESCO6 high-performance computing cluster in Italy. Analyses are presented as summary, waterfall, force and dependency plots. Because data-centre conditions keep changing, the behaviour of feature importance over time is analysed separately.

The authors conclude that explainability improves model transparency and supports collaboration between operators and AI systems; a quantitative assessment of each feature's effect on the output supports operational efficiency and reliability.

Key points

  1. SHAP assigns each feature a Shapley value reflecting its contribution to the model output.
  2. The dataset is real operating data from the ENEA CRESCO6 HPC cluster in Italy.
  3. Explanations are shown as summary, waterfall, force and dependency plots.
  4. Temporal change in feature importance is analysed separately.
  5. Conclusion: explainability improves transparency and operator-AI collaboration.

Using it in design

  • For monitoring products with predictive maintenance, require an explanation view that shows the most influential inputs beside each alert.
  • Document model inputs (sensors, workload, temperature) and schedule periodic review of feature-importance drift.
  • Record in the interface the evidence an operator relied on when accepting or rejecting an AI recommendation.

Who should read it

Data-centre operations teams and engineers designing predictive-maintenance and AI-assisted monitoring.

Publication details

Authors
Yibrah Gebreyesus; Damian Dalton; Davide De Chiara; Marta Chinnici; Andrea Chinnici
Publisher
Electronics (MDPI AG)
Year
2024
Document language
English
Source type
Scientific
Access
Free to read
Licence
CC BY 4.0: share with attribution
Original licence note

Publisher-deposited Crossref licence metadata: https://creativecommons.org/licenses/by/4.0/ (OpenAlex: cc-by); landing page blocks automated fetch, abstract read via Crossref/OpenAlex. Round 1 ingestion retains bibliographic metadata only; no local full text is redistributed.

Citation

Yibrah Gebreyesus; Damian Dalton; Davide De Chiara; Marta Chinnici; Andrea Chinnici (2024). AI for Automating Data Center Operations: Model Explainability in the Data Centre Context Using Shapley Additive Explanations (SHAP). Electronics (MDPI AG). https://doi.org/10.3390/electronics13091628

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Redundancy scenarios in SoSo CAD

Compare normal operation with equipment failures and see served loads and capacity shortfalls in the same view.

Normal operation and failure scenario comparison in SoSo CAD

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.