Analysis of Territorial Risks and Protection Factors for the Business Continuity of Data Centers

Sustainability (MDPI) · Veronica Gazzola, Scira Menoni et al.

A 2023 Sustainability (MDPI) paper proposing a multi-hazard, multi-dimensional method that treats data centre exposure, vulnerability and territorial protection resources across prevention, response and recovery.

On this page

Overview

The paper notes that data centres are critical infrastructure exposed to natural, technological and na-tech events and argues they must guarantee high levels of physical, logical and operational security, reliability and efficiency. Its starting point is recent failure and serious damage cases and the evolution of international and European regulation.

The authors propose an analytical method to assess territorial risk factors for data centres with a multi-risk, multi-dimensional and systemic approach. It gives a more explicit definition of exposed and vulnerable components and recognises resources that can be activated at different territorial levels as protection factors to ensure business continuity, covering the whole resilience cycle from prevention to response and recovery. The Milan case uses two hypothetical site locations, not measurements of real facilities, and the method considers correlated hazards across primary and recovery sites.

Key points

  1. The method is a multi-hazard, multi-dimensional and systemic territorial risk assessment.
  2. Exposed and vulnerable components are defined more explicitly; resources at territorial level are recognised as protection factors.
  3. The whole resilience cycle (prevention, response, recovery) is covered.
  4. The method considers correlated hazards across primary and recovery sites.
  5. The illustrated Milan case uses two hypothetical site locations, not measurements of real facilities.

Using it in design

  • In site selection and recovery site pairing, assess correlated hazards (exposure to the same event) together.
  • Include territorial protection resources (response and recovery capabilities) in the site risk assessment.
  • Systematically list exposed and vulnerable components and link them to the business continuity plan.
  • Add prevention, response and recovery phases separately to the design checklist.

Who should read it

Engineers, planners and risk managers working on data centre site selection, business continuity and risk assessment.

Publication details

Authors
Veronica Gazzola; Scira Menoni; Paolo Ghignatti; Andrea Marini; Roberto Mauri; Giovanni Oldani
Publisher
Sustainability (MDPI)
Year
2023
Document number
15(7), 6005
Document language
English
Source type
Scientific
Access
Free to read
Licence
CC BY 4.0: share with attribution
Original licence note

Article-specific publisher landing page opened on 2026-11-16; copyright statement explicitly links CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Preserve attribution and check separate third-party credit lines before reusing figures. Round 2 ingestion retains bibliographic metadata only; no local full text is redistributed.

Citation

Veronica Gazzola; Scira Menoni; Paolo Ghignatti; Andrea Marini; Roberto Mauri; Giovanni Oldani (2023). Analysis of Territorial Risks and Protection Factors for the Business Continuity of Data Centers. Sustainability (MDPI). 15(7), 6005. https://doi.org/10.3390/su15076005

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Standards pre-assessment in SoSo CAD

Run TS EN 50600 and Tier pre-checks on the model, with missing inputs and items for engineering review listed separately.

Selected rule packs and findings in the SoSo CAD standards panel

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.