Technical guideFree to read2018

Data Center Condenser Protection: How to protect your data center condenser water system during idle operation

Nalco Water / Ecolab

Nalco Water (Ecolab) guide ADV-1828 (2018) compares wet and dry preservation of an idle data-centre condenser-water circuit, covering preservation objectives, restart readiness and maintenance needs.

On this page

Overview

The ADV-1828 guide, published by Nalco Water (Ecolab), is manufacturer guidance on protecting idle data-centre condenser-water circuits (2018). The guide gives a framework for deciding how an idle condenser-water circuit should be preserved.

The guide compares wet and dry preservation methods on restart readiness and maintenance needs. It asks operators to prioritise preservation objectives, because asset protection, restart time, energy use and staffing can conflict.

Before a method is chosen it calls for consulting the system piping diagrams and the cooling-tower manufacturer's recommendations. The guide is a manufacturer document and leaves the choice of method to plant conditions.

Key points

  1. The document compares wet and dry preservation of an idle condenser-water circuit.
  2. Preservation objectives (asset protection, restart time, energy use, staffing) can conflict and must be prioritised.
  3. System piping diagrams and the tower manufacturer's recommendations should be consulted before choosing a method.
  4. Restart readiness and maintenance need are the main criteria for method choice.
  5. The guide was published by Nalco Water (Ecolab) in 2018 under code ADV-1828.

Using it in design

  • In a phased data centre, determine how long the condenser-water circuit will stand idle and decide wet or dry preservation on that duration.
  • Prioritise preservation objectives (corrosion, restart time, energy, staffing) and write them into the operating procedure.
  • Mark drainable or isolable sections and dead legs on the piping diagram.
  • Add the tower manufacturer's preservation recommendations and the water-treatment programme to the commissioning plan.

Who should read it

Mechanical engineers and data-centre operations teams who run cooling towers and condenser-water circuits.

Publication details

Authors
Nalco Water / Ecolab
Publisher
Nalco Water / Ecolab
Year
2018
Document number
ADV-1828
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Official public manufacturer source inspected. No redistribution permission established. Metadata and original brief summaries only; local files are research evidence, not a redistribution package.

Citation

Nalco Water / Ecolab (2018). Data Center Condenser Protection: How to protect your data center condenser water system during idle operation. Nalco Water / Ecolab. ADV-1828. https://www.ecolab.com/-/media/Widen/Nalco-Water/Buildings--Facilities/ADV-1828_Data_Center_Condenser_Protection_pdf.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.