Nihon Spindle KG Series Cooling Tower Heat Rejection Capacity (KG-L Line)
Original title KG-L Heat Rejection Capacity: IP units
Nihon Spindle
Nihon Spindle heat rejection capacity tables for KG-L line normal-type cooling towers: circulating water flow (gpm) at 49 operating conditions, wet bulb 50-90 °F.
On this page
Overview
The document is a wide selection table giving heat rejection capacity in IP units for the standard type and the VR stack version of the Nihon Spindle KG series KG-L line cooling towers. Each model is listed with the circulating water flow (gpm) it can handle at a given condition; model codes span KG-LE31, KG-LG31/41/51/61, KG-LJ31/41/51/61 and KG-LN41/51/61 with letter sizes from D to N.
There are 49 reference conditions. Wet bulb runs 50, 55, 60, 65, 70, 75, 80, 85 and 90 °F, inlet water 67-117 °F, outlet water 57-102 °F, range 9-15 °F and approach 7-12 °F. Additional conditions include near-SI points such as 89.6/80.6 °F water and 69.8-82.4 °F wet bulb. Blank cells mean the condition is outside that model's scope.
Flow values are capped at an upper limit (3 288 gpm in the table). For example the KG-LG61-N reaches the highest flows at high wet bulb and wide approach conditions. The document is a selection table with no method, energy consumption or noise information.
For a data centre designer, the table is used once design wet bulb and required approach/range are set, to check a tower model's flow adequacy. Regional summer wet bulb together with approach directly drives the selection.
Key points
- The table gives flow in gpm in IP units for the KG-L line (normal type) and the VR stack version of the KG series.
- 49 reference conditions are defined; wet bulb is swept from 50 to 90 °F in 5 °F steps.
- Range is 9-15 °F and approach 7-12 °F; the most common pairs are 10/7, 10/10, 10/12, 15/7 and 15/12 °F.
- Inlet water temperatures span 67 to 117 °F and outlet water 57 to 102 °F.
- Series are KG-LE31, KG-LG31/41/51/61, KG-LJ31/41/51/61 and KG-LN41/51/61, with sizes separated by letters D to N.
- A blank cell means the condition is outside the model's scope; the upper flow limit in the table is 3 288 gpm.
- For the same model, flow capacity falls as wet bulb rises or approach shrinks.
Using it in design
- Set the site design wet bulb (for example a 0.4 percent summer value) and required tower outlet water temperature, then read model flow from the nearest condition column.
- A lower approach (for example 7 °F) needs a larger tower; choose approach against chiller or free-cooling circuit targets.
- When checking flow adequacy, leave separate capacity margin for twin towers or cell redundancy (N+1).
- Document unit conversions (gpm, °F) when converting table values to project units.
- The table excludes energy and noise; take fan power and sound level from manufacturer data separately.
Who should read it
Mechanical designers selecting cooling towers for data centre condenser water circuits.
Document contents
- KG series heat rejection capacity: KG-L line (normal type), standard type
- KG-L line with VR stack, circulating water flowrate (gpm)
Publication details
- Authors
- Nihon Spindle
- Publisher
- Nihon Spindle
- Year
- 2022
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Nihon Spindle (2022). KG-L Heat Rejection Capacity: IP units. Nihon Spindle. https://www.spindle.co.jp/en/cooling_tower/pdf4/2022_3-1-2_R7.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.