CoilWall Series: Chilled Water CoilWall Brochure

Original title CoilWall Series: Chilled Water CoilWall

Nortek Data Center Cooling

Nortek Data Center Cooling brochure for the chilled-water CoilWall series: a modular air-cooling wall designed to cut approach temperature, fan power and pump power, with three designs (CWA, CWB, CWC).

On this page

Overview

The brochure presents Nortek Data Center Cooling's CoilWall system as a modular computer room air handler optimised for high-density loads. Its aim is to raise total system efficiency by minimising approach temperature, required fan power and required pump power. Units can be installed stand-alone for cold or hot aisle containment, or joined modularly into a wall for a flooded hall, which enlarges the heat transfer surface and lowers approach temperature as far as possible.

Three options are offered. The CoilWall Array (CWA) uses an array of direct-drive EC plenum fans for higher static pressure and can draw air from the mechanical space or a return duct. The CoilWall Base (CWB) is installed side by side to form an enclosed aisle between the data hall and a maintenance aisle from floor to ceiling, with the maintenance aisle pressurised. The CoilWall Cased (CWC) offers the widest customisation with catalogue-product benefits and can be ducted into the maintenance aisle or a separate mechanical room.

Standard features include an industrial DDC controller with display, continuous monitoring of safety devices, and BACnet and Modbus support. Options include dual power service, an automatic transfer switch, stainless steel coil casing, an anti-vibration structure, high-efficiency MERV filters and customisable coil design. The brochure has no capacity or temperature tables and is promotional.

Key points

  1. The design goal is to reduce approach temperature, fan power and pump power together.
  2. Three products: CoilWall Array (CWA), CoilWall Base (CWB) and CoilWall Cased (CWC).
  3. CWA uses direct-drive EC plenum fans and can be stand-alone, side by side or in a separate mechanical room.
  4. CWB modules form a floor-to-ceiling enclosed aisle and use otherwise empty hall volume for heat transfer.
  5. CWC is ducted for supply and return and can sit in the maintenance aisle or a mechanical room.
  6. The standard DDC controller supports BACnet and Modbus; options include dual power service and ATS.
  7. Options: stainless steel coil casing, anti-vibration structure, MERV filters and custom coil design.

Using it in design

  • Choose between CWA, CWB and CWC by hall type (contained aisle or flooded hall) and calculate fan, coil and duct pressure losses together.
  • State the approach temperature between chilled water supply and target supply air to the manufacturer in the specification for coil design.
  • As the brochure gives no capacity or pressure values, request a project-specific quotation and performance table before selection.
  • Coordinate maintenance-aisle pressurisation and fire compartment requirements with the architect for return and supply access.

Who should read it

Mechanical designers planning chilled-water CRAH and fan wall solutions at hall scale.

Document contents

  1. Nortek Data Center Cooling expertise
  2. Computer room air handler
  3. Operational benefits
  4. Precise temperature controller and shortened option list
  5. CoilWall Array (CWA)
  6. CoilWall Base (CWB)
  7. CoilWall Cased (CWC)

Publication details

Authors
Nortek Data Center Cooling
Publisher
Nortek Data Center Cooling
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Nortek Data Center Cooling CoilWall Series: Chilled Water CoilWall. Nortek Data Center Cooling. https://www.nortekdatacenter.com/wp-content/uploads/2024/02/Nortek-DCC-CoilWall-Series-Brochure.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.