Guidelines: Life Cycle Assessment - LCA Guidelines for Cloud Providers (OCP Sustainability)

Open Compute Project Foundation · Husam Alissa (Microsoft, editor), Julie Sinistore (WSP, editor) et al.

A standard-operating-procedure primer from Microsoft and WSP on running cradle-to-grave life cycle assessments of servers and whole data centres. It is useful background for embodied-carbon modules and EPD-based comparisons. The document carries no publication date.

CC BY-SA 4.0: share with attribution under the same licence

On this page

Overview

The guide has four aims: to give a primer on life cycle assessment (LCA) and greenhouse gas (GHG) accounting, to collect the fundamental questions that set the analysis boundary and parameters and the data needed as a simple starter guide, to anticipate and fill data gaps, and to harmonise the approach so that assessments are comparable. It does not cover LCA in the detail of the standards; it is a high-level guide to deciding whether LCA is the right tool and which key aspects to include.

An LCA follows the four phases of ISO 14040 and 14044: goal and scope, life cycle inventory (data collection), impact assessment (modelling) and interpretation. LCA quantifies not only GHG but also other impacts such as energy and water. The system boundary can be cradle-to-gate or cradle-to-grave; for a data centre, a cradle-to-grave boundary lets hotspots be identified in raw materials, production, use and end of life. The GHG Protocol instead classes emissions as Scope 1 (direct on-site), Scope 2 (purchased electricity) and Scope 3 (15 categories, upstream and downstream).

The two approaches differ in how they file emissions: in LCA, the production (embodied) emissions of servers fall in the production phase, while in GHG accounting they sit under Scope 3 upstream category 1; Scope 1 and 2 mostly fall in the use phase of an LCA. An LCA result can be used for Scope 1, 2 and 3 reporting, but needs recategorising. Also, under the GHG Protocol, renewable-energy purchases can bring market-based direct energy emissions to zero, whereas the ISO 14040 and 14044 LCA methodology does not follow market-based accounting.

The applied part works through an example: computing the environmental-impact difference between an existing server and a newer model. The impacts are GHG, primary energy use and blue water consumption; the system boundary is cradle-to-grave (including building, servers, racks, network gear and support equipment); and the functional unit for a cloud service is provisioning one virtual machine (VM). Data collection is the most time-consuming stage; gaps are filled with documented assumptions, product EPDs or proxy datasets, and sensitivity analysis is run. For external communication, especially a comparative LCA, an ISO-conformant report reviewed by a panel of three independent experts is required. Allocation between co-products was not part of the data centre analysis.

Key points

  1. LCA follows the four ISO 14040 and 14044 phases: goal and scope, inventory, impact assessment and interpretation.
  2. GHG Protocol accounting groups emissions into Scopes 1-3, with 15 Scope 3 categories; LCA can also quantify non-GHG impacts such as water and energy.
  3. Server production (embodied) emissions fall in the production phase in LCA and under Scope 3 upstream category 1 in GHG accounting; the categories differ between the two.
  4. For a cloud service, the example functional unit is provisioning one virtual machine; the impacts are GHG, primary energy and blue water consumption.
  5. The cradle-to-grave boundary for a data centre covers raw materials, production, use and end of life of the building, servers, racks, network and support equipment.
  6. In a general data centre LCA, use-phase energy is usually the main driver of GHG and water; in production, servers rather than building materials stand out, and within servers SSDs and DIMMs.
  7. Data gaps are filled with documented assumptions, EPDs or proxy datasets, and sensitivity analysis is recommended.
  8. External communication requires an ISO-conformant report and critical review by a panel of three independent experts.
  9. Allocation between co-products was not part of the data centre analysis.

Using it in design

  • When building an embodied-carbon module, keep production-phase emissions of servers, building, cooling and electrical equipment separate, and fix the mapping between Scope 3 upstream reporting and LCA phases in a table.
  • In comparative analyses (for example two servers or two cooling options), define the functional unit first and choose a cradle-to-grave boundary; leave out items that are the same in both options (for example network equipment) to reduce data-collection effort.
  • Where no EPD exists for equipment, use a proxy dataset and write these assumptions and the sensitivity analysis into the report.
  • For results that will be shared externally, add an ISO-conformant report and a critical-review plan to the project budget and schedule.
  • Show renewable-energy purchases separately in market-based GHG reporting and in LCA results; the two approaches do not follow the same rule.

Who should read it

Data-centre designers carrying out sustainability and embodied-carbon analysis, LCA teams at cloud and hardware providers, and managers responsible for Scope 1-3 reporting.

Document contents

  1. Introduction: life cycle assessment and greenhouse gas accounting (similarities and differences)
  2. Goal and Scope
  3. Data Collection
  4. Modeling
  5. Reporting format for ISO
  6. Conclusion
  7. Glossary and references

Related standards

  • ISO 14040
  • ISO 14044
  • GHG Protocol

Read the document

ocp-lca-guidelines-cloud-providers.pdf

PDF · 0.4 MB · English

CC BY-SA 4.0: share with attribution under the same licence

The document is provided unaltered because its licence permits redistribution.

Publication details

Authors
Husam Alissa (Microsoft, editor); Julie Sinistore (WSP, editor); Kari Lio (Microsoft, editor)
Publisher
Open Compute Project Foundation
Year
Year not stated
Document language
English
Source type
Industry body
Access
Open licence (downloadable)
Licence
CC BY-SA 4.0: share with attribution under the same licence
Licence evidence
www.opencompute.org
Original licence note

Creative Commons Attribution-ShareAlike 4.0 International; licence verified from the licence statement in the document itself. Attribution to the authors and publisher is kept; adaptations must keep the same licence.

Citation

Husam Alissa (Microsoft, editor); Julie Sinistore (WSP, editor); Kari Lio (Microsoft, editor) Guidelines: Life Cycle Assessment - LCA Guidelines for Cloud Providers (OCP Sustainability). Open Compute Project Foundation. https://www.opencompute.org/documents/lca-sop-in-ocp-document-submission-template-docx-pdf/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.