White Paper: Sustainability as the Fifth Tenet - A Practical Guide to Sustainability for the OCP Community, Version 1.0

Open Compute Project Foundation · Jonmichael Hands (Chia Network), Jordan Tse (Meta) et al.

Sets out how OCP's Sustainability Project (made OCP's fifth tenet after the 2022 Global Summit) defines sustainability: transparency and reporting, circularity and efficiency. For operators it explains GHG scopes as they apply to data centres and gives a table of recommended metrics with the standard or framework for each. It is a compact crosswalk between data-centre KPIs and reporting frameworks; the document is undated.

CC BY-SA 4.0: share with attribution under the same licence

On this page

Overview

The paper contrasts the standard approach to sustainability (minimising the environmental impact of products and services, a do-less-bad view) with the broader one OCP is taking: operating responsibly and positively impacting the world, combining collaboration with openness and efficiency. The first step is transparency by reporting and disclosing environmental impacts, metrics and improvement over time. The GHG Protocol is the most widely used corporate greenhouse gas accounting standard; Scope 1 and 2 reporting is becoming common, while Scope 3 is much harder because it needs transparency of all activities across the value chain.

For data-centre operators the scopes are read as follows: Scope 1 covers emissions created in operation such as backup generators and on-site vehicles; Scope 2 is purchased power, from the utility or through a power purchase agreement; Scope 3 includes the embodied carbon of the building, racks, servers and electrical equipment, and end-of-life waste. A single-occupant data centre typically counts the whole data-centre load as Scope 2; a multi-tenant data centre may assign IT loads to tenants' Scope 2, but there is no industry consensus on when and how.

Recommended metrics are given as a matrix of 23 key metrics and frameworks under energy, GHG, water, waste and land headings: ISO/IEC 30134-2 for PUE and renewable energy factor, ISO/IEC 30134-6 for energy reuse factor (ERF), ISO/IEC 30134-8 for carbon usage effectiveness (CUE), ISO/IEC 30134-9 for site water use and water usage effectiveness (WUE), the GHG Protocol or ISO 14064 for GHG scopes, and GRI 306 for waste. For hour-by-hour supply and consumption matching there is not yet a framework or standard. For equipment suppliers the paper recommends LCA under ISO 14040 and EPDs under ISO 14025, and disclosure of software, database and modelling rules, because the same equipment can yield different embodied-carbon figures depending on them.

The circularity section gives a priority order of use extension, reuse, repair, recycling and disposal; reuse is the highest-value flow and needs secure transfer of ownership and data sanitisation. On efficiency it notes that PUE has driven cooling improvements but does not show the carbon intensity of the power used or how efficiently IT power is used. It states that sustainability is now the fifth OCP tenet and that submissions are evaluated on five criteria; the approach is based on transparency rather than prescription.

Key points

  1. Scope 1 (for operators): on-site sources such as backup generators; Scope 2: purchased power; Scope 3: embodied carbon of building, racks, servers and electrical equipment, and end of life.
  2. There is no industry consensus on whether multi-tenant operators should assign IT load emissions to tenants' Scope 2.
  3. Metric table maps PUE to ISO/IEC 30134-2, ERF to 30134-6, CUE to 30134-8, WUE and site water to 30134-9, and GHG scopes to the GHG Protocol or ISO 14064.
  4. Hourly supply and consumption matching is listed as a metric with no framework or standard available yet.
  5. The metric matrix has 23 key metrics across energy, GHG, water, waste and land and biodiversity.
  6. Equipment suppliers are advised to do LCA under ISO 14040, publish EPDs under ISO 14025 and disclose software, database and modelling rules.
  7. Circularity priority order: use extension, reuse, repair, recycling, disposal.
  8. PUE does not show the carbon intensity of power used or how efficiently IT power is used; metrics such as CUE and HUE address that gap.
  9. Sustainability is now the fifth OCP tenet (alongside openness, efficiency, scale and impact); proposals are evaluated on all five.

Using it in design

  • Set data-centre KPI definitions according to the crosswalk: ISO/IEC 30134-2 for PUE, 30134-6 for ERF, 30134-8 for CUE, 30134-9 for WUE; state in design reports which standard the figure is calculated to.
  • Settle scope boundaries at design stage: track generator fuel as Scope 1, grid and PPA electricity as Scope 2 and building and equipment embodied carbon as Scope 3 separately; in multi-tenant projects define the tenant load-allocation method in the contract.
  • Add a request for ISO 14040-conformant LCA and ISO 14025 EPDs, with the software and database disclosed, to supplier specifications.
  • When reporting metrics that have no standard yet, such as hourly matching, state the method explicitly.
  • In equipment selection, weigh circularity criteria such as ease of reuse and repair (disassembly, interoperability, standard racks) and an end-of-life ownership-transfer and data-sanitisation plan.

Who should read it

Data-centre operators and designers, equipment suppliers, managers responsible for sustainability reporting and teams submitting proposals to OCP.

Document contents

  1. Introduction and approach to sustainability
  2. Transparency: metrics and reporting (data-centre operators, hardware suppliers)
  3. Circularity (use extension, reuse, sharing, repair, refurbish, remanufacture, recycling; interoperability)
  4. Efficiency (PUE, CUE, HUE and product efficiency)
  5. Sustainability as the 5th OCP Tenet: Three Guiding Principles
  6. License and about OCP

Related standards

  • ISO/IEC 30134-2
  • ISO/IEC 30134-6
  • ISO/IEC 30134-8
  • ISO/IEC 30134-9
  • GHG Protocol
  • ISO 14064

Read the document

ocp-sustainability-fifth-tenet.pdf

PDF · 1.2 MB · English

CC BY-SA 4.0: share with attribution under the same licence

The document is provided unaltered because its licence permits redistribution.

Publication details

Authors
Jonmichael Hands (Chia Network); Jordan Tse (Meta); Alex Rakow (Schneider Electric); Tiffany Jin (OCP)
Publisher
Open Compute Project Foundation
Year
Year not stated
Document number
Version 1.0
Document language
English
Source type
Industry body
Access
Open licence (downloadable)
Licence
CC BY-SA 4.0: share with attribution under the same licence
Licence evidence
www.opencompute.org
Original licence note

Creative Commons Attribution-ShareAlike 4.0 International; licence verified from the licence statement in the document itself. Attribution to the authors and publisher is kept; adaptations must keep the same licence.

Citation

Jonmichael Hands (Chia Network); Jordan Tse (Meta); Alex Rakow (Schneider Electric); Tiffany Jin (OCP) White Paper: Sustainability as the Fifth Tenet - A Practical Guide to Sustainability for the OCP Community, Version 1.0. Open Compute Project Foundation. Version 1.0. https://www.opencompute.org/documents/ocp-sustainability-pdf/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.