Onda Dry Cooler Range: Configuration and Model Ranges

Original title Dry Cooler Range

ONDA

Onda S.p.A.'s two-page dry cooler sheet: six flat and V-shape series from 19 to 2,019 kW, 70-230 models each, with adiabatic options giving a 7-9 K air temperature reduction.

On this page

Overview

The sheet summarises Onda's flat and V-shape liquid cooler range in six series. Coils use copper tubes with high-efficiency corrugated aluminium fins; fans use AC and EC technology, selected for low noise and smart speed regulation. The maker states more than 25 configurable options and the ability to build customised solutions.

Series ranges: FN flat single row (230 models, 1-5 fans, 19-490 kW), FND flat dual row (190 models, 4-14 fans, 78-990 kW), FLV V-shape single row (80 models, 1-8 fans, 61-1,060 kW), GLV V-shape single row (100 models, 1-10 fans, 68-1,312 kW), FVD V-shape dual rows (70 models, 4-16 fans, 230-1,618 kW) and MVL V-shape dual rows (90 models, 4-20 fans, 235-2,019 kW). Flat series offer horizontal or vertical airflow. The sheet does not state the fluid, temperature or air condition behind the capacities.

The adiabatic system is said to allow operation at high ambient temperature with low water consumption and no Legionella, and comes in three options: BS basic spray (air saturation 70%, temperature reduction 7 K), OS Onda spray (80%, 8 K) and PD pad system (90%, 9 K). The document is a range summary for one product family and has no detailed capacity tables.

Key points

  1. FN: 230 models, 1-5 fans, 19-490 kW; FND: 190 models, 4-14 fans, 78-990 kW (flat, single and dual row).
  2. FLV: 80 models, 1-8 fans, 61-1,060 kW; GLV: 100 models, 1-10 fans, 68-1,312 kW (V-shape single row).
  3. FVD: 70 models, 4-16 fans, 230-1,618 kW; MVL: 90 models, 4-20 fans, 235-2,019 kW (V-shape dual rows).
  4. Flat series offer horizontal or vertical airflow.
  5. Coils are copper tube with corrugated aluminium fins; fans are AC or EC with smart speed regulation.
  6. Adiabatic options: BS spray 70% saturation and 7 K, OS spray 80% and 8 K, PD pad 90% and 9 K air temperature reduction.
  7. More than 25 configurable options and customised solutions.

Using it in design

  • The sheet gives no fluid, entering temperature or air condition for its capacity ranges, so select through the maker's selection software or quotation.
  • For a data centre, calculate the effect of the adiabatic option (7-9 K reduction) on dry cooler leaving temperature during the hottest hours, and the water use.
  • Compare V-type and flat types on footprint, height and wind effect; dual-row models give higher kW density.
  • For adiabatic systems, add water quality, drainage and Legionella prevention to the operating procedure.

Who should read it

Mechanical designers screening dry cooler families.

Document contents

  1. Dry cooler range
  2. Adiabatic system options
  3. Series ranges: FN, FND, FLV, GLV, FVD, MVL

Publication details

Authors
ONDA
Publisher
ONDA
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

ONDA Dry Cooler Range. ONDA. https://www.onda-it.com/wp-content/uploads/2023/03/Air-DRY-COOLER-RANGE.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.