Consulting-Specifying Engineer, 2015, Guide or technical publication
An article in which Bill Kosik walks through the engineering inputs that actually determine a facility's PUE, from economizer control limits to electrical losses at part load.
Guide or technical publication
2015
Read at publisher (opens in a new tab)↗
Jacobs, 2023, Guide or technical publication
This Jacobs white paper surveys measures to reduce data centre energy, water and embodied carbon. It offers a broad framework from cooling strategies and water reuse to low-carbon concrete and altern…
Guide or technical publication
2023
Read at publisher (opens in a new tab)↗
Uptime Institute Journal, 2014, Guide or technical publication
Uptime Institute Journal article tracing Uptime's Fault Tolerant Power Compliance Specification and why dual-corded IT underpins Tier III and IV.
Guide or technical publication
2014
Read at publisher (opens in a new tab)↗
Uptime Institute Journal, 2016, Guide or technical publication
An Uptime Institute Journal article reviewing economizer types and how to apply them without breaking Tier III/IV objectives.
Guide or technical publication
2016
Read at publisher (opens in a new tab)↗
Data Center Frontier, 2026, Guide or technical publication
An article profiling Edged US's standardized AI campus model built around closed-loop waterless cooling from sister company ThermalWorks, with design targets for the Aurora and Irving projects.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Uptime Institute Journal, 2025, Guide or technical publication
An Uptime Institute Journal article explaining why large transformer-model training clusters create synchronized, millisecond-scale step loads that stress power distribution.
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
Lawrence Berkeley National Laboratory / The Brattle Group, 2026, Guide or technical publication
A technical brief surveying US large-load tariffs and electric service agreements for data centres, classifying design elements by prevalence and trend.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Uptime Institute Intelligence, 2022, Guide or technical publication
Uptime Institute Intelligence's Briefing Report 76, covering types of EMP, their effects on electronics and the grid, and recommendations for EMP risk assessment.
Guide or technical publication
2022
Read at publisher (opens in a new tab)↗
U.S. Environmental Protection Agency (ENERGY STAR), 2026, Guide or technical publication
ENERGY STAR guidance on embedded data centres (server rooms, closets and small localised data centres), explaining why they escape scrutiny and what consolidation options exist.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2025, Guide or technical publication
The base specification from the OCP Sustainability project and the iMasons Climate Accord carbon disclosure workstream defines the minimum information vendors must supply with an embodied carbon figu…
Guide or technical publication
2025
PDF
International Energy Agency, 2026, Guide or technical publication
A joint IEA and Korea Energy Economics Institute (KEEI) study (27 March 2026) extending Energy and AI to East Asia. It covers data-centre demand and grid planning, the determinants of AI data-centre…
Guide or technical publication
2026
PDF
U.S. DOE Federal Energy Management Program / Lawrence Berkeley National Laboratory, 2013, Guide or technical publication
An LBNL case study of energy assessments at DoD high-performance computing data centres, grouping measures into packages with typical cost per kW of IT and simple payback.
Guide or technical publication
2013
Read at publisher (opens in a new tab)↗
U.S. Environmental Protection Agency (ENERGY STAR), 2024, Guide or technical publication
A one-page EPA memo announcing that SPEC SERT version 2.0.8 is the version to use for ENERGY STAR server certification. It tells anyone storing or comparing server efficiency scores which tool versio…
Guide or technical publication
2024
PDF
U.S. Environmental Protection Agency (ENERGY STAR), 2020, Guide or technical publication
A short ENERGY STAR test method used with the Version 2.x storage specification. It incorporates the SNIA Emerald 4.0.0 measurement procedure and fixes test conditions: ambient window, regional input…
Guide or technical publication
2020
PDF
U.S. Environmental Protection Agency (ENERGY STAR), 2023, Guide or technical publication
The test method used with the ENERGY STAR Computer Servers Version 4.0 specification to obtain idle and active state power. It sets input power, ambient conditions, measurement instrument requirement…
Guide or technical publication
2023
PDF
U.S. Environmental Protection Agency (ENERGY STAR), 2022, Guide or technical publication
The U.S. EPA's current ENERGY STAR eligibility criteria for block and file I/O data-centre storage products. It defines power-supply efficiency, minimum active-state performance-per-watt, adaptive…
Guide or technical publication
2022
PDF
U.S. Environmental Protection Agency (ENERGY STAR), 2016, Guide or technical publication
The U.S. EPA's ENERGY STAR criteria for rack-mounted large network equipment (switches and routers with more than 11 ports). It sets PSU efficiency and power-factor floors, Energy Efficient Ethernet…
Guide or technical publication
2016
PDF
U.S. Environmental Protection Agency (ENERGY STAR), 2017, Guide or technical publication
The method for measuring efficiency and input power factor under the ENERGY STAR UPS Version 2.0 criteria. It rests on IEC 62040-3 for ac-output UPSs, IEC 62040-5-3 Annex F for high-voltage dc-output…
Guide or technical publication
2017
PDF
Burns & McDonnell, 2025, Guide or technical publication
A Burns & McDonnell white paper on battery energy storage systems (BESS) as a campus-scale power asset for hyperscale and AI data centres.
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
The Green Grid, 2026, Guide or technical publication
This 2026 Green Grid video discussion introduces Energy Usage Impact (EUI) and the DCRE family (WUI, ITWC) as holistic metrics for AI-era data centers, arguing that PUE alone is no longer sufficient.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
European Union Agency for the Operational Management of Large-Scale IT Systems in the Area of Freedom, Security and Justice (eu-LISA), 2026, Guide or technical publication
A 2026 eu-LISA report covering data centre energy efficiency and sustainability KPIs, EU and international regulation, a small survey and innovation projects.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
EPRI (Electric Power Research Institute), 2026, Guide or technical publication
The programme site for EPRI's DCFlex collaborative, which studies how data centres can flex load to support grid reliability and faster interconnection.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2025, Guide or technical publication
A CoolIT presentation at the OCP EMEA Summit 2025 reporting early results of a programme to find safe coolant velocity limits in single-phase direct liquid cooling loops.
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
CBRE Data Centre Solutions (deck hosted on SlideShare by ICT Footprint.eu), 2018, Guide or technical publication
Mark Acton's presentation surveys the standards landscape a designer faces (ASHRAE thermal classes, Uptime Tiers, TIA-942-B, ISO/IEC 30134, EN 50600, the EU Code of Conduct, EMAS) and clears up commo…
Guide or technical publication
2018
Read at publisher (opens in a new tab)↗