Philippine Skills Framework for Software Development and Security
Department of Information and Communications Technology / Philippine Software Industry Association
The 2024 framework from the Philippine DICT and PSIA defines data-centre facilities management as a competency running from level 2 to level 5, from routine maintenance to capacity planning.
On this page
Overview
The document is version 1.0 of a skills framework produced by the DICT ICT Industry Development Bureau with the Philippine Software Industry Association (PSIA) and launched in April 2024. It brings career pathways, role descriptions and the functional and enabling skills tied to each role into one structure for software development and cybersecurity. Its readers are workers, employers and institutions that write curricula.
The data-centre material sits in the Operations and Support track. The career map includes roles such as Associate Data Center Operations Engineer and Data Center Operations Engineer. The first covers systems maintenance and monitoring, equipment set-up and shift-based on-call work; later roles add incident resolution, input to business-continuity planning and suitability analysis of vendor products.
The central Data Center Facilities Management competency is defined on a six-level scale. Level 2 means keeping performance and security levels of hardware and facility systems and carrying out routine installation and decommissioning. Level 3 means identifying ideal environmental conditions and restoring performance, level 4 means capacity and resource planning, and level 5 means producing a facilities management plan that sets infrastructure requirements and charts capacity growth.
It is not a technical design standard and gives no numeric thresholds, loads or redundancy values. Its value is in separating clearly which responsibility belongs to which competency level in a data-centre organisation: routine equipment work, preventive maintenance, commissioning and decommissioning, resource planning and facility strategy.
Key points
- Version 1.0 was launched in April 2024 for the software development and security sector.
- Data Center Facilities Management is defined from level 2 to level 5; the Associate Data Center Operations Engineer role expects level 2 and the Data Center Operations Engineer level 3.
- Level 2: maintain performance and security levels of hardware and facility systems; routine equipment installation and decommissioning.
- Level 3: identify ideal environmental conditions and restore performance against security and service-level requirements; knowledge of preventive maintenance and system recovery procedures.
- Level 4: capacity and resource planning for data-centre facilities, plus management protocols and security guidelines.
- Level 5: a facilities management plan defining infrastructure and technical requirements and charting capacity enhancements.
- Entry-level roles are expected to be on call, with shifts including nights, weekends and holidays.
- The separate Infrastructure Deployment competency covers site preparation, installation testing and decommissioning decisions across levels 1 to 4.
Using it in design
- When planning the operating organisation, map maintenance, commissioning and capacity-planning duties to these levels and record the required competency for each role in the handover package.
- Decide who performs commissioning and decommissioning tasks; leave complex installations to level 3 and above staff.
- Design capacity and energy monitoring dashboards around the reports that level 4-5 decision makers will use.
- Align the operations training plan and SoSo CAD user roles with these competency steps.
Who should read it
Data-centre operations managers, HR and training planners, and design and operating firms building teams in the Philippine market.
Document contents
- Messages
- Introduction
- Why Do We Need the Philippine Skills Framework?
- Career Map
- Skill Maps: Operations and Support, Product Development, Cybersecurity, Governance Risk and Compliance
- Overview of Functional Skills and Competencies (FSC)
- PSF Proficiency Level Descriptors
- Functional Skills and Competencies (FSC)
- Enabling Skills and Competencies (ESC)
- Technical Guide
Publication details
- Authors
- Department of Information and Communications Technology / Philippine Software Industry Association
- Publisher
- Department of Information and Communications Technology / Philippine Software Industry Association
- Year
- 2024
- Document number
- Version 1.0
- Document language
- English
- Source type
- Government / public
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Public official source inspected; no document-specific commercial redistribution permission established. Original short summaries and metadata only; downloads are local research evidence. Official TESDA-hosted framework; source authorship is distinguished from the hosting agency.
Citation
Department of Information and Communications Technology / Philippine Software Industry Association (2024). Philippine Skills Framework for Software Development and Security. Department of Information and Communications Technology / Philippine Software Industry Association. Version 1.0. https://www.tesda.gov.ph/Uploads/File/Philippine%20Skills%20Framework/ICT/Philippine%20Skills%20Framework%20for%20Software%20Development%20and%20Security.pdf