Planer HA-S HS air-cooled chiller catalogue (2023)

Planer

The Planer HA-S HS catalogue covers R-410A scroll air-cooled chillers; the standard range is 4-480 HP (9.6-975 kW at 7/12 °C water and 35 °C air), with capacity given at three reference conditions.

On this page

Overview

Planer's 2023 catalogue presents air-cooled water chillers for process cooling and HVAC. Standard models span 4-480 HP, or 9.6-975 kW at 12/7 °C water and 35 °C air. Data rest on common industrial process conditions and the relevant Eurovent conditions. Compressors are scroll, reciprocating and screw types; coils are copper-tube aluminium-fin, with DX evaporators.

The HA-S HS series covers 12 scroll-compressor models, P 041 to P 501, with R-410A (GWP 2088). The catalogue gives three reference conditions. In condition 1, water at 15/20 °C and air at 25 °C give 20.7-188.0 kW and EER 4.2-4.9. In condition 2, with air at 32 °C, capacity falls to 17.9-171.8 kW. In condition 3, water at 7/12 °C and air at 35 °C give 13.5-125.3 kW and EER 2.3-2.7.

EER is based on total power input; tables list total compressor power and total power input on separate rows. Each model has one compressor. Fan sound pressure is given per EN 13487 at 10 m, with a correction table for other distances. Pump and water tank are standard on scroll and reciprocating units and optional on screw units.

The catalogue lists extra options: free-cooling Eco-Chiller, low-temperature glycol units from 0 to -40 °C, an adiabatic/evaporative cooling accessory, EC fans and fan speed control. For higher capacities and special designs it refers users to the manufacturer's engineering department.

Key points

  1. Standard range 4-480 HP; 9.6-975 kW at 12/7 °C water and 35 °C air.
  2. HA-S HS: R-410A (GWP 2088), scroll compressors; 12 models (P 041-P 501).
  3. Condition 1 (15/20 °C water, 25 °C air): 20.7-188.0 kW, EER 4.2-4.9.
  4. Condition 2 (15/20 °C water, 32 °C air): 17.9-171.8 kW.
  5. Condition 3 (7/12 °C water, 35 °C air): 13.5-125.3 kW, EER 2.3-2.7.
  6. One compressor per model; total compressor power 2.9-27.9 kW.
  7. Evaporator water flow at Δt = 5 °C is 3.6-32.3 m³/h (condition 1).
  8. Sound levels per EN 13487 at 10 m; free-cooling, adiabatic and EC fan options available.

Using it in design

  • Read capacity at the reference condition closest to project water and air temperatures; at 7/12 °C and 35 °C capacity is roughly 33-35% lower than at 15/20 °C and 25 °C.
  • In EER comparisons, do not mix compressor-only power with total power input; fan power is in the total.
  • Assess the R-410A GWP (2088) against environmental targets and refrigerant regulations.
  • Use conditions 2 and 3 for capacity loss at high ambient temperatures and consider the adiabatic accessory where needed.
  • On sound-limited sites, convert the 10 m sound pressure to your position with the distance correction.

Who should read it

Mechanical designers selecting air-cooled chillers for process cooling and small to mid-size data rooms.

Document contents

  1. Technical specifications
  2. Compressors
  3. Air-cooled condensers and free-cooling coils
  4. Evaporators and fans
  5. Unit construction and microprocessor control
  6. Pumps and water tanks
  7. Options
  8. HA-S HS reference conditions 1, 2 and 3 tables

Publication details

Authors
Planer
Publisher
Planer
Year
2023
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Planer (2023). Planer HA-S HS air-cooled chiller catalogue (2023). Planer. https://www.planerchillers.com/storage/products/catalogs/ha-s-serisi-katalog.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.