Pumpiran Vertical Multistage Centrifugal In-line Pump PCR Series catalogue

Original title Vertical Multistage Centrifugal In-line Pump PCR Series

Pumpiran

The Pumpiran PCR catalogue covers 12 families of vertical multistage in-line pumps from PCR 1 to PCR 150, with 0.7-180 m³/h flow, 275 m head, -15 to +120 °C and 25-33 bar maximum operating pressure.

On this page

Overview

The 34-page catalogue presents Pumpiran's PCR series of vertical multistage centrifugal in-line pumps. The range consists of PCR 1, 3, 5, 10, 15, 20, 32, 45, 64, 90, 120 and 150. Each family has a performance-curve page and a dimensions-and-weights page. Curve pages show flow in m³/h, L/min and U.S. GPM against head in metres, with NPSH, power and efficiency curves as well.

General specifications (repeated on each dimension page): output size 25 to 125 mm, capacity 0.7-180 m³/h, head 275 m, operation temperature -15 to +120 °C, single phase 220-240 V and three phase 380-415 V, 50 Hz, insulation class F, enclosure class IP55 and ambient 50 °C. Flanges are DIN (DIN-ANSI-JIS for PCR 1) in the PN16-25-40 range, with connections from DN25-32 up to DN125.

The construction section lists, for PCR 1-20, a cast-iron (EN-GJL-200) pump head, stainless steel (1.4301) impeller, 1.4057 shaft, EPDM o-ring, PTFE neck ring and a cartridge mechanical seal. PCR 32-90 use a cast-iron EN-GJL-250 pump head and motor bracket. A maximum operating and inlet pressure table is given by family and stage range: for example, PCR 1 has 25 bar operating pressure at 2-36 stages, PCR 45 has 30 and 33 bar and PCR 120 and PCR 150 have 30 bar.

The pressure rule is that inlet pressure plus the pressure against a closed valve must not exceed the maximum operating pressure. The catalogue carries certifications such as ISO 9001, ISO 14001, ISO 45001 and ISO/IEC 17025. Hydraulic selection can be done from the curve pages, which are graphical rather than numerical tables.

Key points

  1. 12 pump families: PCR 1, 3, 5, 10, 15, 20, 32, 45, 64, 90, 120, 150.
  2. Overall range: flow 0.7-180 m³/h, head 275 m, output size 25-125 mm.
  3. Operating temperature -15 to +120 °C; ambient 50 °C; insulation class F; IP55.
  4. Supply single phase 220-240 V or three phase 380-415 V, 50 Hz.
  5. Maximum operating pressure 10-33 bar by family and stage; for example 25 bar at 2-36 stages for PCR 1, 3 and 5.
  6. Materials (PCR 1-20): cast iron EN-GJL-200 pump head, stainless steel 1.4301 impeller and chamber, cartridge mechanical seal.
  7. DIN flange PN16-25-40; connections DN25-32 (small) to DN125 (PCR 150).
  8. Pressure rule: inlet pressure + closed-valve pressure < maximum operating pressure.

Using it in design

  • Overlay the duty point on the family curves and verify suction lift and inlet pressure from the NPSH curve.
  • Compare inlet pressure plus closed-valve pressure with the family's maximum operating pressure table (for example 10, 16, 25 bar).
  • Confirm material and seal suitability for -15 to +120 °C and glycol mixtures with the manufacturer.
  • Carry the flange class (PN16-25-40) and DN size into pipe class and header design.
  • For duty/standby pump layouts, put net weight and dimensions into the pump room layout.

Who should read it

Mechanical designers selecting high-pressure vertical pumps for chilled-water and pressure-boosting circuits.

Document contents

  1. Certifications
  2. Performance range
  3. Maximum operating and inlet pressures
  4. Construction and materials
  5. PCR 1 to PCR 150 curves
  6. PCR 1 to PCR 150 dimensions and weights

Publication details

Authors
Pumpiran
Publisher
Pumpiran
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Pumpiran Vertical Multistage Centrifugal In-line Pump PCR Series. Pumpiran. http://pumpiran.org/erp/upload/pumpiran.co/Nasb-catalog/VERTICAL%20MULTI%20STAGE%20STEEL%20PUMPS.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.