ABB Compact ATS: Compact without Compromise (OTM_C_D)

Original title ABB Compact ATS compact without compromise 1SCC308001B0201

ABB

ABB catalogue for the 40, 63 and 125 A OTM_C_D Compact ATS family: fixed (C20D) and adjustable (C21D) versions, 2 to 4 poles, IEC 60947-6-1 testing and mains/generator transfer delays.

On this page

Overview

The catalogue presents ABB's single-housing automatic transfer switch (ATS) that needs no external power supply. The manufacturer states about 40% less cabinet space than conventional solutions. The device is tested to IEC 60947-6-1 and the listed applications include residential, commercial and industrial buildings as well as telecom and data centres as a standby-power transfer device. All live parts are enclosed and an external handle allows manual transfer in an emergency.

The family has two versions. OTM_C20D is fixed: predefined delay times and voltage thresholds, for network/network applications. OTM_C21D is adjustable: for network/network and network/genset applications, with configurable transfer and back-switching delays, adjustable voltage thresholds and Modbus RTU through a plug-in module. Tables list 2, 3 and 4 pole units at 40, 63 and 125 A with ordering codes and weights (1.75 kg for 3 poles, 2.00 kg for 4 poles).

Technical features give rated operational voltage 220-240 V single phase and 380-415 V three phase (±20%), frequency 50/60 Hz ±10%, operating temperature -20 to +55 °C, altitude up to 2000 m and IP20 front panel. Voltage sensing accuracy is 5% on the fixed and 3% on the adjustable version. On the C21D the undervoltage threshold is 0.7-0.95 Ue, overvoltage 1.05-1.3 Ue, transfer delay 0-30 s, back-switching delay 0-900 s and generator stop delay 240 s.

The document is a product catalogue: it describes an integrated transfer device rather than a contactor and control-relay combination. Voltage unbalance and invalid-frequency detection are not marked for either version; where that is required a different ATS controller is needed.

Key points

  1. Frame sizes OTM40, OTM63, OTM125; 2, 3 and 4 poles; 1.75 kg for 3 poles, 2.00 kg for 4 poles.
  2. Rated voltage 220-240 V (single phase) and 380-415 V (three phase), ±20%; 50/60 Hz ±10%.
  3. Voltage sensing accuracy 5% on C20D, 3% on C21D; Uimp 6 kV, overvoltage category III.
  4. C21D: undervoltage 0.7-0.95 Ue, overvoltage 1.05-1.3 Ue, transfer delay 0-30 s, back-switching delay 0-900 s, generator stop 240 s.
  5. C20D is for network/network only; network/genset transfer needs the C21D.
  6. Rated current in an enclosure at 40 °C is 40, 63 and 125 A; at 60 °C it is 32, 50 and 100 A.
  7. Conditional short-circuit rating 50 kA at 415 V with up to 125 A gG fuse; Icw 2.5 kA at 690 V for 1 s.
  8. Mechanical endurance 10 000 operations; loss per pole 1.6, 2.8 and 6.3 W (40, 63, 125 A).
  9. Operating temperature -20 to +55 °C, altitude up to 2000 m, IP20 front panel.

Using it in design

  • Choose the C21D for a generator-backed data hall incomer; the C20D does not suit generator transfer.
  • Coordinate fuses to the catalogue's conditional short-circuit table, for example at most 125 A gG for 50 kA at 415 V.
  • In a 60 °C enclosure rate the switches at 32/50/100 A instead of 40/63/125 A.
  • If transfer on voltage unbalance or frequency deviation is required, record in the specification that this range does not detect it.
  • Tune back-switching and generator stop delays together with the UPS and generator load acceptance.

Who should read it

Electrical engineers and panel builders designing low-voltage distribution and standby-power transfer.

Document contents

  1. Compact without compromise
  2. Safety and protection, space saving, affordable range
  3. Ordering information (OTM_C20D fixed, OTM_C21D adjustable)
  4. Technical features and functionality
  5. Time delays and signals
  6. Technical data OTM40...125
  7. Accessories

Publication details

Authors
ABB
Publisher
ABB
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

ABB ABB Compact ATS compact without compromise 1SCC308001B0201. ABB. https://library.e.abb.com/public/012ee8cbadee4756a726670c61372a13/ABB_compacts_ATS_1SCC308001B0201_21-11.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.