Legrand Keor HPi 33 EVO 10-40 kW Three-Phase UPS Brochure
Original title HPi 33 EVO 10–40 kW brochure
Legrand
The Legrand HPi 33 EVO is a 10-40 kW (kVA = kW) three-phase double-conversion on-line UPS with efficiency up to 95%, above 98% in ECO mode, parallel operation of up to 4 units and class VFI-SS-111.
On this page
Overview
The document is Legrand's brochure (October 2024) for the HPi 33 EVO three-phase UPS family (10, 20, 30 and 40 kVA; 10-40 kW). The unit is a true on-line double-conversion design based on APFC PWM IGBT with unity output power factor (kVA = kW). Target uses are IT, infrastructure, education, manufacturing, healthcare and small to medium data centres. The brochure also describes Legrand's sustainability approach (EPD/PEP, ISO 14025) and service offering.
Features are summarised under performance, ease of use, flexibility and protection. The IGBT rectifier and inverter give low THDi; a 5-inch touch display with SNMP, Modbus, RS232 and USB provides remote monitoring, and the unit is stated to use up to 30% less space than a conventional UPS. For flexibility there is N+X redundancy with up to 4 units in parallel, a common battery configuration for up to 2 units, a temperature-compensated battery charger and a flexible DC bus. An optional integrated isolation transformer is available. Protection includes a dust filter, conformal-coated boards, phase reversal correction and built-in input, output and maintenance bypass switches.
The technical table lists input of 380/400/415 VAC (3PH+N+PE), a 320-476 VAC voltage range, 45-55 Hz, input PF above 0.99 and input THDi (at rated linear load) below 4% (below 3% for higher ratings). Output is 400 VAC ±1% (settable 380/400/415), and online overload is 110% for 1 hour, 125% for 10 min and 150% for 1 min. Batteries are VRLA or Li-ion, external, nominal 240 or 480 VDC. Operating temperature is 0-40 °C, IP20, noise at most 65 dBA, and standards are IEC 62040-1/-2/-3.
Key points
- Models 10, 20, 30 and 40 kVA; kW equals kVA (at 35 °C); IEC class VFI-SS-111.
- Double-conversion efficiency up to 93-95%; above 98% in ECO mode.
- Input 380/400/415 VAC, 320-476 VAC range; input PF above 0.99; input THDi below 4% (below 3% at higher ratings).
- Online overload: 110% for 1 hour, 125% for 10 min, 150% for 1 min; bypass: 110% continuous, above 150% for 10 ms.
- N+X parallel of up to 4 units; common battery configuration for up to 2 units.
- Battery: external, VRLA or Li-ion, 240 or 480 VDC.
- Up to 30% less space than conventional UPS; 5-inch touch display; RS232, RS485, relay contact, optional SNMP.
- 0-40 °C, IP20, at most 65 dBA; IEC 62040-1/-2/-3, CE and RoHS.
Using it in design
- Compare critical load in kW directly to the UPS rating; with output PF 1, kVA and kW are equal (at 35 °C).
- Evaluate N+X parallel of up to 4 units against the target Tier for redundancy.
- Match battery chemistry (VRLA or Li-ion) and the 240 or 480 VDC bus to the battery selection.
- Weigh the 98% ECO-mode efficiency against the loss of conditioning in bypass operation and load sensitivity.
- Use input THDi and PF in generator sizing.
Who should read it
Electrical designers selecting three-phase UPS units for small and medium data centres and IT rooms.
Document contents
- Sustainability and environment
- HPi 33 EVO introduction
- Performance, ease of use, flexibility, protection
- Technical specification table
- Customer services and service
Publication details
- Authors
- Legrand
- Publisher
- Legrand
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Legrand HPi 33 EVO 10–40 kW brochure. Legrand. https://ups.legrand.com/media/document/Brochure%20Keor%20HPi%2033%20EVO.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.