Petra APSa Air-Cooled Screw Chiller (R-134a, microchannel condenser, 2019 catalogue)

Original title Petra APSa technical catalogue, 50 Hz SI performance p.57

Petra

Petra Engineering's September 2019 APSa catalogue: air-cooled R-134a chiller with semi-hermetic screw compressors and a microchannel condenser; single-piece 14,400 mm unit at 2,110, 2,040 and 1,935 kW (550, 580 and 600 TR).

On this page

Overview

The catalogue presents the Petra APSa air-cooled liquid chiller series: semi-hermetic screw compressors, microchannel (MCHE) condenser coils and R-134a refrigerant. The manufacturer is ISO 9001:2015 and ISO 14001:2015 certified, its main products are UL and ETL listed and air-cooled chillers are rated to the AHRI standard. Units are 100 percent factory tested and commissioned.

Highlighted features: superior efficiency meeting or exceeding the new ASHRAE 90.1 levels at both full and part load; low sound power levels measured to BS ISO 3744 (suited to schools, hospitals and residential areas); and a compact footprint. APSa is offered as a single-piece, single power entry unit, 14,400 mm (567 inch) long, at 2,110, 2,040 and 1,935 kW (nominal 550, 580 and 600 tons), claiming the largest capacity in a single chiller model.

Microchannel condenser coils are cheaper than traditional coils; copper tube aluminium fin or copper tube copper fin coils are available as corrosion resistance options. Low ambient options: head pressure management by fan speed control, operation down to 0 °C and -17 °C, cooler tape heater protection down to 0, -18 and -29 °C ambient. Contents cover physical data, performance data, electrical data, unit clearances and a guide specification (to page 111).

Key points

  1. Single-piece, single power entry unit; length 14,400 mm (567 inch).
  2. Nominal capacities are 2,110, 2,040 and 1,935 kW (550, 580 and 600 TR).
  3. Semi-hermetic screw compressors, R-134a, microchannel (MCHE) condenser coils.
  4. Efficiency meets or exceeds the new ASHRAE 90.1 levels at full and part load.
  5. Sound power levels are measured to BS ISO 3744; positioned for sound-sensitive surroundings.
  6. Coil options: copper tube aluminium fin or copper tube copper fin, chosen for corrosion resistance.
  7. Low ambient: operation down to 0 °C and -17 °C; cooler tape heater down to 0, -18 and -29 °C ambient.
  8. Rated to the AHRI standard; 100 percent factory tested and commissioned.

Using it in design

  • For large plants, weigh reducing unit count with single-unit capacities of 1,935-2,110 kW against the load share lost when one unit fails under N+1 redundancy.
  • Check rooftop or yard layout and air recirculation with the 14,400 mm length and the unit clearance table.
  • In coastal and corrosive environments, assess whether copper-copper coils or a protective coating are needed instead of microchannel coils.
  • Set the low ambient option from the site's lowest temperature.
  • Compare sound power level with neighbouring limits; take selection data at AHRI conditions.

Who should read it

Mechanical designers selecting air-cooled screw chillers for large chilled water plants.

Document contents

  1. Outstanding features
  2. Standard and optional features
  3. Microprocessor controller
  4. Physical data
  5. Model layout
  6. Selection procedure
  7. Performance data
  8. Electrical data
  9. Application data
  10. Unit clearance
  11. Guide specification

Publication details

Authors
Petra
Publisher
Petra
Year
2019
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Petra (2019). Petra APSa technical catalogue, 50 Hz SI performance p.57. Petra. https://petramisr.com/files/APSa-Sep2019.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.