Petra APSa Air-Cooled Screw Chiller (R-134a, microchannel condenser, 2019 catalogue)
Original title Petra APSa technical catalogue, 50 Hz SI performance p.57
Petra
Petra Engineering's September 2019 APSa catalogue: air-cooled R-134a chiller with semi-hermetic screw compressors and a microchannel condenser; single-piece 14,400 mm unit at 2,110, 2,040 and 1,935 kW (550, 580 and 600 TR).
On this page
Overview
The catalogue presents the Petra APSa air-cooled liquid chiller series: semi-hermetic screw compressors, microchannel (MCHE) condenser coils and R-134a refrigerant. The manufacturer is ISO 9001:2015 and ISO 14001:2015 certified, its main products are UL and ETL listed and air-cooled chillers are rated to the AHRI standard. Units are 100 percent factory tested and commissioned.
Highlighted features: superior efficiency meeting or exceeding the new ASHRAE 90.1 levels at both full and part load; low sound power levels measured to BS ISO 3744 (suited to schools, hospitals and residential areas); and a compact footprint. APSa is offered as a single-piece, single power entry unit, 14,400 mm (567 inch) long, at 2,110, 2,040 and 1,935 kW (nominal 550, 580 and 600 tons), claiming the largest capacity in a single chiller model.
Microchannel condenser coils are cheaper than traditional coils; copper tube aluminium fin or copper tube copper fin coils are available as corrosion resistance options. Low ambient options: head pressure management by fan speed control, operation down to 0 °C and -17 °C, cooler tape heater protection down to 0, -18 and -29 °C ambient. Contents cover physical data, performance data, electrical data, unit clearances and a guide specification (to page 111).
Key points
- Single-piece, single power entry unit; length 14,400 mm (567 inch).
- Nominal capacities are 2,110, 2,040 and 1,935 kW (550, 580 and 600 TR).
- Semi-hermetic screw compressors, R-134a, microchannel (MCHE) condenser coils.
- Efficiency meets or exceeds the new ASHRAE 90.1 levels at full and part load.
- Sound power levels are measured to BS ISO 3744; positioned for sound-sensitive surroundings.
- Coil options: copper tube aluminium fin or copper tube copper fin, chosen for corrosion resistance.
- Low ambient: operation down to 0 °C and -17 °C; cooler tape heater down to 0, -18 and -29 °C ambient.
- Rated to the AHRI standard; 100 percent factory tested and commissioned.
Using it in design
- For large plants, weigh reducing unit count with single-unit capacities of 1,935-2,110 kW against the load share lost when one unit fails under N+1 redundancy.
- Check rooftop or yard layout and air recirculation with the 14,400 mm length and the unit clearance table.
- In coastal and corrosive environments, assess whether copper-copper coils or a protective coating are needed instead of microchannel coils.
- Set the low ambient option from the site's lowest temperature.
- Compare sound power level with neighbouring limits; take selection data at AHRI conditions.
Who should read it
Mechanical designers selecting air-cooled screw chillers for large chilled water plants.
Document contents
- Outstanding features
- Standard and optional features
- Microprocessor controller
- Physical data
- Model layout
- Selection procedure
- Performance data
- Electrical data
- Application data
- Unit clearance
- Guide specification
Publication details
- Authors
- Petra
- Publisher
- Petra
- Year
- 2019
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Petra (2019). Petra APSa technical catalogue, 50 Hz SI performance p.57. Petra. https://petramisr.com/files/APSa-Sep2019.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.