Saravel general catalogue, printed p.24
Saravel
The 2010 Saravel general catalogue lists fan coils, air handlers, packaged units and chillers from 8.9 to 574.8 tons, with capacity and weight, from an Iranian HVAC maker founded in 1960.
On this page
Overview
Saravel says it was founded in 1960 as the first HVAC equipment manufacturer in Iran and is now a leading air-conditioning manufacturer in the Middle East. The catalogue (CAT-GEN-2010) covers fan coils, air handling units, condensers, coils, packaged units, chillers, cooling towers, fans, ventilators and unit heaters, and notes custom units for oil and petrochemical, plastics and ceramics industries.
The chiller systems section includes air-cooled mini chillers, reciprocating liquid chillers (SLCH-10 to SLCH-80), open-type liquid chillers (SLCO-175 to SLCO-700), air-cooled packaged and split liquid chillers (SPLCH) and scroll liquid chillers. Each table lists model, actual capacity (tons), compressor input power (kW), weight and dimensions.
For example, SLCH-10-1W gives 9.4 tons at 8.8 kW, SLCO-175-1W gives 171.1 tons at 113.3 kW and SLCO-700-2W gives 574.8 tons at 429 kW. Water-cooled capacities are based on 95°F condenser leaving water and 45°F cooler leaving water. The SPLCH series has 16 models; the text states 10 to 320 tons while the table lists SPLCH-10-1 (8.9 tons, 9.0 kW) to SPLCH-100-2 (72.9 tons, 79.8 kW). The scroll liquid chiller covers 10 to 100 tons with R22, brazed-plate evaporator and shell-and-tube condenser.
Key points
- The catalogue dates from 2010 (CAT-GEN-2010); the manufacturer was founded in 1960.
- In the reciprocating SLCH series, SLCH-10-1W gives 9.4 tons and 8.8 kW and SLCH-50-1W gives 41.3 tons and 33.1 kW.
- The open-type SLCO series runs from 171.1 tons (113.3 kW) to 574.8 tons (429 kW).
- Water-cooled capacities are based on 95°F condenser leaving and 45°F cooler leaving water.
- The air-cooled split SPLCH series has 16 models; the table lists 8.9 to 72.9 tons.
- The scroll liquid chiller covers 10-100 tons with R22, brazed-plate evaporator and shell-and-tube condenser.
- Tables give compressor input power, not total plant input.
- Evaporator flow for SPLCH models ranges from 21 to 175 GPM.
Using it in design
- Use the actual capacity in the table, not the nominal ton, as the selection value; SLCH-10-1W gives 9.4 tons instead of a nominal 10.
- Compare water-cooled capacities only at 95°F condenser and 45°F evaporator leaving conditions; ask the manufacturer for corrections at other conditions.
- Add pumps, tower and auxiliaries to compressor input to build the total energy budget.
- Because the catalogue dates from 2010, confirm current models, refrigerants and efficiency data with the manufacturer.
Who should read it
Mechanical designers and procurement engineers comparing commercial and industrial chillers in the Middle East market.
Document contents
- Fan Coils
- Air Handling Units
- Condensers
- Coils
- Packaged Units
- Chiller Systems
- Cooling Tower
- Airfoil Fans
- Utility Fans
- Ventilators
- Unit Heaters
Publication details
- Authors
- Saravel
- Publisher
- Saravel
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document