Technical guideFree to readYear not stated

Soeteck STS 1U Rack Mount Static Transfer Switch: Model Range Table

Original title Soeteck STS 1U model range table

Soeteck

Soeteck STS 1U series rack-mount static transfer switch: 10, 16 and 32 A models, typical 6 ms transfer between two independent sources, 200-240 V AC, 50/60 Hz, 430 × 260 × 44.4 mm.

On this page

Overview

The document is the product page of Soeteck's 1U rack-mount static transfer switch (STS) from China. The unit transfers automatically between two independent power sources, with a typical transfer time of 6 ms. Data centres, telecom, industrial automation, medical equipment, security and surveillance systems and financial institutions are listed as applications, with emphasis on preventing outages in redundant UPS configurations.

There are three models: SY-STS-1U-10A, SY-STS-1U-16A and SY-STS-1U-32A. Input and output are 2-pole, 200-240 V (configurable), 50/60 Hz. Connection options: the 10 A model has 2 × IEC C14 inputs and 7 × IEC 10 A outputs; the 16 A model has 2 × IEC C20 inputs, 8 × IEC C13 and 1 × IEC C19 outputs; the 32 A model has terminal blocks for input and output. Every model has an LCD display and an RS-485 communication interface (the description text says RS485, the model table RS-485).

Physical values: all three models are 430 mm wide, 260 mm deep and 44.4 mm high, weighing 5.0 kg for 10 A and 16 A and 6.0 kg for 32 A. Standards listed are IEC/EN (EMC) compliance and CE. The technical specifications and brochure sections are marked 'coming soon', so apart from transfer time the document gives no transfer trigger thresholds, overload or short-circuit values.

Key points

  1. Three models: SY-STS-1U-10A, -16A and -32A; 1U rack-mount.
  2. Typical transfer time 6 ms; automatic transfer between two independent sources.
  3. Input/output 2-pole, 200-240 V (configurable), 50/60 Hz.
  4. 10 A: 2 × IEC C14 input, 7 × IEC 10 A output; 16 A: 2 × IEC C20 input, 8 × IEC C13 + 1 × IEC C19 output; 32 A: terminal blocks.
  5. LCD display and RS-485 communication interface.
  6. Size 430 × 260 × 44.4 mm; weight 5.0 kg (10/16 A), 6.0 kg (32 A).
  7. IEC/EN (EMC) compliance, CE.

Using it in design

  • For single-phase dual-source rack loads (for example two separate UPS outputs), choose 10, 16 or 32 A against the rack load total.
  • Compare the 6 ms typical transfer with the server power supply hold-up time.
  • Carry the connector type (IEC C14/C20/C13/C19 or terminal block) into PDU and cable design.
  • In the 1U layout, check rack depth (260 mm) and weight.
  • Ask the manufacturer for protocol information to connect the RS-485 interface to monitoring.

Who should read it

Electrical engineers designing dual-source supply in data-centre, telecom and industrial facilities.

Document contents

  1. Overview
  2. Key features
  3. Model range
  4. Technical specifications

Publication details

Authors
Soeteck
Publisher
Soeteck
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Soeteck Soeteck STS 1U model range table. Soeteck. https://soeteck.com/en/products/critical-power/static-transfer-switches/soeteck-sts-series-rack-mount-static-transfer-switch-1u-10-16-32a/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.