Soeteck STS 8U Rack Mount Static Transfer Switch: Model Range Table

Original title Soeteck STS 8U model range table

Soeteck

Soeteck STS 8U series rack-mount static transfer switch: 32, 40, 63, 100 and 125 A models, typical 5 ms transfer at 340-420 V input, 3P/4P configuration, break-before-make switching.

On this page

Overview

The document is the product page of Soeteck's 8U rack-mount static transfer switch (STS). The unit transfers between primary and backup sources in a typical 5 ms and is designed for sensitive loads in data centres, communication hubs and industrial automation. Input and output configuration is 3P or 4P and voltage is 340-420 V (configurable). The break-before-make switching mechanism removes the risk of cross-phase connection.

There are five models: SY-STS-8U-32A, -40A, -63A, -100A and -125A. All offer a typical 5 ms transfer time, an LCD display and a communication interface (the description text says RS232, the model table RS-485). Dimensions are 430 × 420 × 350 mm for all models; weights are 32 kg for 32 A, 35 kg for 40 A, 38 kg for 63 A, 42 kg for 100 A and 45 kg for 125 A. IEC/EN and CE compliance is stated.

The document stresses scalability and system redundancy and suits transfer between a UPS and a generator or between two UPSs. The technical specifications and brochure sections are marked 'coming soon', so the document gives no transfer trigger thresholds, overload and short-circuit values or physical interface detail.

Key points

  1. Five models: SY-STS-8U-32A, -40A, -63A, -100A, -125A; 8U rack-mount.
  2. Typical transfer time 5 ms; break-before-make switching.
  3. 3P/4P configuration, 340-420 V (configurable), 50/60 Hz.
  4. Size 430 × 420 × 350 mm.
  5. Weight 32 kg (32 A), 35 kg (40 A), 38 kg (63 A), 42 kg (100 A), 45 kg (125 A).
  6. LCD display; communication interface is RS-485 in the model table and RS232 in the description text.
  7. IEC/EN and CE compliance.

Using it in design

  • Select the current rating (32 to 125 A) against the downstream load total and whether the system is three-phase or four-wire.
  • Compare the typical 5 ms transfer with the critical load's outage tolerance.
  • Weigh the reduced cross-phase risk of break-before-make switching together with the need for the two UPS outputs to be synchronous.
  • Check the 8U layout and weight (32 to 45 kg) against rack handling and floor loading.
  • Confirm the communication interface (RS-485 or RS232) with the monitoring system.

Who should read it

Electrical engineers designing dual-source supply in data-centre, telecom and industrial facilities.

Document contents

  1. Overview
  2. Model range
  3. Technical specifications

Publication details

Authors
Soeteck
Publisher
Soeteck
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Soeteck Soeteck STS 8U model range table. Soeteck. https://soeteck.com/en/products/critical-power/static-transfer-switches/soeteck-sts-series-rack-mount-static-transfer-switch-8u-32-40-63-100-125a/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.