Milleteknik SINUS UPS 300W M product page
Milleteknik
Product page for Milleteknik's 230 V, 300 W wall-mounted offline UPS built for door and access applications, with room for two 14 Ah batteries, controlled charging and two alarm outputs.
On this page
Overview
The page presents the 300 W M model of Milleteknik's SINUS UPS family. The article number is ME01U0021FP003 and the E-number is 52 136 21. It is described as a 230 V, 300 W wall-mounted UPS with space for two 14 Ah batteries, and the manufacturer positions it mainly as a backup supply for door environments.
The technical description is short and centres on battery management and monitoring. The unit has controlled charging, which the manufacturer says prevents batteries from being overcharged and extends their life. Controlled charging works by charging at a lower voltage to reduce wear; the trade-off is that the batteries reach a full 100 percent charge more slowly, so applications that need quick recovery should assess the charging behaviour separately.
On the interface side there is one PICTO output, one emergency lighting output, an LED for alarm indication and three cable glands. Two alarm outputs are provided: the first reports mains failure and incorrect charge voltage, the second reports an aged battery and a UPS that is not working. Mounting is on a wall, installation is fixed, accepted battery types are lead-acid and AGM, the unit is fanless and no battery box can be connected to it.
The page is a product catalogue entry rather than a data-centre document. Its typical use is the emergency opening of doors and other passages, primarily accessibility passages. For a data-centre designer, its value is in seeing what class of device is used to back up small security and access-control loads, and how alarm and battery information is exposed.
Key points
- Article number ME01U0021FP003, E-number 52 136 21; rated 230 V and 300 W.
- The wall-mounted enclosure holds two 14 Ah batteries; no external battery box can be connected.
- Accepted battery types are lead-acid and AGM.
- Controlled charging uses a lower charge voltage, extending battery life but slowing the approach to a 100 percent charge.
- One PICTO output, one emergency lighting output and an alarm LED are fitted.
- Alarm output 1: mains failure and incorrect charge voltage; alarm output 2: aged battery and non-working UPS.
- The unit is fanless, intended for fixed installation and has three cable glands.
- Typical use: emergency opening of doors and other passages, mainly accessibility-related.
Using it in design
- Sum door, access-control and emergency-release loads against the 300 W limit; load and required runtime must fit what two 14 Ah batteries can deliver.
- Because no battery box can be attached, choose a larger model or a series with external battery support when the runtime requirement grows.
- Wire the alarm outputs into the building management or security system so mains failure and battery ageing are monitored.
- Include the slower full recharge caused by controlled charging in the recharge-time calculation where outages are frequent.
Who should read it
Electrical designers and system integrators who select backup power for doors, access control and security systems.
Publication details
- Authors
- Milleteknik
- Publisher
- Milleteknik
- Year
- Year not stated
- Document language
- Unverified
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Milleteknik Milleteknik SINUS UPS 300W M product page. Milleteknik. https://www.milleteknik.se/produkt/ups-sinus-300w-m/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.