Hydroo VDROO VF/VX/VN/VD Series, 60 Hz Vertical Multistage Pump Catalogue
Original title Hydroo: VDROO VF/VX/VN/VD Series, 60 Hz
Hydroo
Hydroo's VDROO series catalogue covers vertical multistage stainless centrifugal pumps from 1 to 210 m3/h (BEP) in 13 sizes, rated at 60 Hz, 3500 rpm and air-free water at 20 °C.
On this page
Overview
The catalogue presents Hydroo's VDROO vertical multistage centrifugal pumps made at its factory in Palol de Revardit (Catalonia, Spain). The series has VF (cast iron with AISI304), VX (AISI304), VN (AISI316) and VD (duplex stainless on some sizes) versions and their pump sets with motor and variable-frequency drives. The pump is vertical, non-self-priming and multistage, driven by a standard motor through a coupling; inlet and outlet are on the same plane at the pump base.
The maker lists these features: a cartridge mechanical seal that allows seal maintenance without removing the motor; oval, round, threaded and Victaulic connection options; each pump individually tested with results available; 1-210 m3/h in 13 sizes; an IE3 totally enclosed two-pole standard motor (IP55, class F); compliance with EU ErP Regulation 547/2012 with a higher MEI grade than the minimum. Standard 60 Hz voltages are 1x220 V, 3x220/440 V and 3x265/460 V.
Operating conditions are thin, clean, non-flammable, non-explosive liquid without solid granules or fibres; liquid temperature -15 to +120 °C, ambient up to +40 °C and altitude up to 1000 m. Applications include cooling water systems, municipal and domestic water supply and boosting, irrigation, industrial services, boiler feed and condensate, water treatment and washing. The catalogue also covers NPSH and suction-lift calculation (H = Pb x 10.2 - NPSH - Hf - Hv - Hs, minimum 0.5 m margin), benefits of parallel pump operation, material lists, dimensions and performance curves per size. Maximum pressure ranges 14-26 bar by size; the test basis is 60 Hz, 3500 rpm and air-free water at 20 °C.
Key points
- 1-210 m3/h (BEP) in 13 sizes; vertical, non-self-priming, multistage.
- Test basis: 60 Hz, 3500 rpm, air-free water at 20 °C.
- Material versions: VF (cast iron + AISI304), VX (AISI304), VN (AISI316), VD (duplex).
- Standard motor: IE3, two-pole, IP55, class F; 60 Hz voltages 1x220, 3x220/440, 3x265/460 V.
- Liquid temperature -15 to +120 °C; ambient up to +40 °C and altitude up to 1000 m.
- Maximum pressure about 14-26 bar by size; PN25/PN40 flanged, threaded or Victaulic connections.
- Cartridge mechanical seal; EU 547/2012 ErP compliance.
Using it in design
- For cooling-water and chilled-water loops, select the pump from the flow and head point on the 60 Hz, 3500 rpm curve; the catalogue is not directly usable on a 50 Hz supply.
- Check NPSH and suction loss with the catalogue formula and keep at least a 0.5 m margin.
- For glycol or corrosive loops choose material version (VX, VN, VD) and seal type to suit the liquid.
- Assess parallel pumps for redundancy (N+1) and variable-flow systems; compare the VFD pump set option with the energy target.
- Compare maximum working pressure by size with system static and test pressure.
Who should read it
Mechanical designers and specification engineers selecting pumps for cooling-water and auxiliary water loops.
Document contents
- Presentation
- Pump range and main features
- Main technical benefits
- Pump, application and operation conditions
- Selection and NPSH
- Materials
- Performance curves and tables
- Dimensions
Publication details
- Authors
- Hydroo
- Publisher
- Hydroo
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Hydroo Hydroo: VDROO VF/VX/VN/VD Series, 60 Hz. Hydroo. https://www.hydroo.com.tr/wp-content/uploads/2020/08/vf-vx-vn-vd-katalog.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.