Imas's 2025 catalogue lists its air-cooled HS LS close-control series in 13 single-circuit models from 7.12 to 45.6 kW and 14 dual-circuit models from 21 to 105.1 kW.

On this page

Overview

Izmir-based Imas publishes a catalogue of close-control air conditioning units for IT rooms, UPS rooms, archives and laboratories. It explains how precision cooling differs from comfort cooling through design parameters such as 24/7/365 operation, low energy use, ease of maintenance and interface with central control systems.

The model code starts with HS followed by capacity and compressor count. CS means a cooling-only split unit and LS a split unit for cooling, heating, humidification and dehumidification. Compressor options are inverter (Si) and scroll (S). The structure is self-supporting hot-dip galvanised panels, double skin, glass-wool insulated and RAL 7016 epoxy-polyester coated.

The table gives two groups. The single-compressor series (HS 7.1 to HS 46.1) covers 7.12 to 45.6 kW with airflow of 1,460 to 9,340 m³/h. The dual-compressor series (HS 21.2 to HS 105.2) covers 21 to 105.1 kW and 4,300 to 21,530 m³/h. The table does not label capacity as net sensible capacity.

Standard equipment includes hermetic and BLDC inverter scroll compressors, an isothermal immersed-electrode humidifier, AC or EC backward-curved radial fans and an electric heater. The EC fan option is stated to give about 15% lower operating cost. Condensing temperature range is given as +7.5 to +50 °C.

Key points

  1. Single-compressor series (HS 7.1 LS to HS 46.1 LS): 13 models, 7.12-45.6 kW, 1,460-9,340 m³/h.
  2. Dual-compressor series (HS 21.2 LS to HS 105.2 LS): 14 models, 21-105.1 kW, 4,300-21,530 m³/h.
  3. 27 model rows in total; compressor types range from ZP29 to ZP182.
  4. Condensing temperature range +7.5/+50 °C.
  5. Humidifier capacity 1.5-3 kg/h (small models) or 5-8 kg/h; heater 3-15 kW.
  6. Example: HS 46.1 LS has 45.6 kW capacity, 12.3 kW compressor power and 17.1 kW total power.
  7. CS is cooling only; LS covers cooling, heating, humidification and dehumidification.
  8. An EC fan option is stated to give about 15% lower operating cost.

Using it in design

  • Because catalogue capacity is not labelled net sensible, obtain the net sensible capacity and rating conditions from the manufacturer in writing.
  • Calculate hall load as sensible heat and add a unit for N+1 redundancy in selection.
  • For LS units include humidifier and heater electrical power in the supply panel calculation.
  • Verify airflow against cabinet layout and under-floor or direct-discharge arrangement.
  • Define the BMS interface and EC fan speed control separately in the specification.

Who should read it

Mechanical designers selecting close-control units for server rooms, UPS rooms and small data halls.

Document contents

  1. About us
  2. Precision cooling technology
  3. Close control unit: structure and notation
  4. Close control unit: technical table

Publication details

Authors
İmas
Publisher
İmas
Year
2025
Document number
2025-1
Document language
Turkish
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

İmas (2025). İmas Hassas Kontrollü Klima Cihazları 2025-1. İmas. 2025-1. https://imasklima.com.tr/wp-content/uploads/2025/08/HASSAS-KONTROLLU-KLIMA-2025-4.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.