Network Environments 800-AC-CW Fan Wall (chilled-water fan wall)
Original title Network Environments Fan Wall Rev2.0
Network Environments
Network Environments' 800-AC-CW fan wall is an EC-fan chilled-water air handler designed for hot aisle containment, offering 220 to 430 kW of cooling across six models.
On this page
Overview
The brochure presents a chassis-based, modular fan wall. The unit consists of filters, cooling coil and fans and is designed for hot aisle containment. It aims for a large supply area, low air resistance and more uniform airflow. It is built from a steel frame and insulated steel panels, with front access for maintenance.
The manufacturer states that the new-generation EC fan is moulded in one piece from composite material, that air volume is adjustable from 0 to 100 % and that fans can be replaced while running (hot-swap). Control includes automatic balancing, a graphical interface, group control, standard RS485 and an optional network interface, with a 7-inch touch screen. Options include an ATS dual power switch, water temperature sensors, filter differential-pressure monitoring and a choice of corrosion class.
In the technical table the models are 800-AC-CW220, 250, 270, 320, 360 and 430. Cooling capacity is 220, 250, 270, 320, 360 and 430 kW, water-side pressure drop 45-55 kPa, external pressure 150 Pa and rated power 10.4-20.3 kW. Connections are DN80 (220 and 250 kW) and DN100 (270-360 kW). Conditions: return air 37 °C / 25 % RH, supply 25 °C, water 15/21 °C, G4 filter.
Additional benefits claimed are over 10 % higher fan utilisation than conventional precision units and 10-15 % overall energy saving. No raised floor is needed and hot and cold aisle sizes are not limited by floor tiles. Side air supply is offered for buildings with insufficient ceiling height and for high-density cabinets.
Key points
- Six models: 220 / 250 / 270 / 320 / 360 / 430 kW cooling capacity (return air 37 °C / 25 % RH, supply 25 °C, water 15/21 °C, G4 filter).
- Water-side pressure drop 45-55 kPa; external pressure 150 Pa; rated power 10.4-20.3 kW.
- Water connection DN80 (220-250 kW) and DN100 (270-360 kW).
- EC fan air volume adjustable 0-100 %; fans are hot-swappable.
- Standard 7-inch touch screen and RS485; options: ATS dual power, filter differential-pressure monitoring, water temperature sensors.
- The manufacturer states 10-15 % overall energy saving against conventional precision units.
- No raised floor needed; side supply suits halls with limited ceiling height.
- Example sizes: 2,700 x 2,350 x 1,500 mm (220-250 kW) to 3,000 x 3,800 x 1,000 mm (430 kW).
Using it in design
- In halls with hot aisle containment, place the fan wall along the wall and confirm with CFD that cold air reaches the aisle cross-section evenly.
- The water regime is 15/21 °C, so set the chilled-water plant's high-temperature regime (and free-cooling potential) to match.
- Add the DN80 and DN100 connections and the 45-55 kPa pressure drop to the pipe and pump calculation.
- Where dual feeds are required, put the ATS option and fan N+x redundancy into the specification.
- The air volume column is misprinted in the table; obtain air flow from the manufacturer in writing.
Who should read it
Mechanical engineers designing chilled-water air distribution for large data halls.
Document contents
- Product structure
- Product features
- Technical data
- Other options
- Additional benefits
Publication details
- Authors
- Network Environments
- Publisher
- Network Environments
- Year
- Year not stated
- Document language
- Unverified
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Network Environments Network Environments Fan Wall Rev2.0. Network Environments. https://www.networkenvironments.com/wp-content/uploads/2025/06/NetEnv_FanWall-Rev2.0.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.