Pentax: CM-CMG-CA-4CA EN 733, 50 Hz

Pentax

Pentax's 50 Hz technical tables for CM, CMG, CA and 4CA EN 733 end-suction centrifugal pumps, giving motor output P2, electrical input P1 and head at explicit flow columns.

On this page

Overview

The Pentax document contains 50 Hz technical tables for the CM, CMG, CA and 4CA families built to EN 733 dimensions. The tables cover end-suction centrifugal pumps and give motor output (P2) and electrical input (P1) in separate columns, so shaft power and power drawn from the grid can be read separately when selecting a pump.

The CM performance table lists head at explicitly stated flow columns for each model. The stated applications include circulation in cooling and heating circuits, so the document can be used directly when selecting pumps for chilled-water circuits.

Key points

  1. EN 733 end-suction centrifugal pumps: CM, CMG, CA and 4CA families, 50 Hz.
  2. P2 (motor output) and P1 (electrical input) are given in separate columns.
  3. The CM performance table lists head at explicit flow columns.
  4. Stated applications include circulation in cooling and heating circuits.

Using it in design

  • Read the duty point from the table's flow columns and compare head with the circuit loss.
  • In electrical design, use P1 to determine grid power and cable size per pump.
  • In energy calculations, show the P2 and P1 difference (motor efficiency) separately.
  • Consider in the layout the interchangeability that EN 733 dimensions bring for standby and replacement pumps.

Who should read it

Mechanical designers selecting end-suction pumps for chilled-water circuits.

Publication details

Authors
Pentax
Publisher
Pentax
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Pentax Pentax: CM-CMG-CA-4CA EN 733, 50 Hz. Pentax. https://www.pentax-pumps.it/pentax/wp-content/uploads/sites/5/2025/07/CM-EN733-50HZ.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.