Technical guideFree to readYear not stated

LOVATO Electric ATP complete enclosed automatic transfer switches

LOVATO Electric

LOVATO Electric's ATP series offers enclosed automatic transfer switches with a 230 Vac auxiliary supply and four-pole contactors at 45, 60, 80, 100, 125 and 160 A (AC1), equivalent to 31-111 kVA.

On this page

Overview

LOVATO Electric's Brazilian catalogue page for automatic transfer controllers lists the ATL series transfer controllers and the ATP series of complete enclosed ATS units. Six ATP order codes define enclosed switches rated 45, 60, 80, 100, 125 and 160 A (AC1). All have a 230 Vac auxiliary supply and four-pole contactors and control two power sources.

Each code gives an apparent power equivalent and dimensions next to the current: ATP0045 is 45 A / 31 kVA, ATP0060 60 A / 42 kVA, ATP0080 80 A / 55 kVA, ATP0100 100 A / 69 kVA, ATP0125 125 A / 87 kVA and ATP0160 160 A / 111 kVA. Dimensions are 500 x 400 x 200 mm for the 45-100 A codes and 600 x 400 x 250 mm for the 125 and 160 A codes.

The page also lists the ATL900 controller (for three power sources and two tie breakers, 110-240 Vac and 12/24/48 Vdc supply, EXP expansion modules, built-in RS485, 3PH+N current inputs) and the ATLDPS1 dual power supply module (measurement of the voltages at the supply inputs that power motorised breakers and changeover switches, configurable 110/230 Vac). The page carries the published current, supply voltage and dimension data for each code; transfer time and short-circuit withstand are not given in this listing.

Key points

  1. Six ATP codes: 45, 60, 80, 100, 125 and 160 A, AC1.
  2. Auxiliary supply 230 Vac; four-pole contactors; two power sources.
  3. Apparent power equivalents: 31, 42, 55, 69, 87 and 111 kVA.
  4. Dimensions 500 x 400 x 200 mm for 45-100 A; 600 x 400 x 250 mm for 125 and 160 A.
  5. Code format ATP0045T4A230C600A (the current step is embedded in the code).
  6. ATL900 controller handles three sources and two tie breakers; 110-240 Vac and 12/24/48 Vdc supply; RS485.
  7. ATLDPS1 module gives a configurable 110/230 Vac dual supply.
  8. Transfer time and short-circuit withstand are not given on the page.

Using it in design

  • Compare load current with the AC1 ratings (45-160 A); for motor loads or high inrush, check the AC rating separately.
  • Match the apparent power equivalent (kVA) to generator and transformer sizing, but treat load current as the limiting value.
  • Carry the enclosure size (500 x 400 x 200 or 600 x 400 x 250 mm) into the electrical room or wall layout.
  • Identify on the drawing the source and protection of the 230 Vac auxiliary supply.
  • For three-source or bus-tie systems, prefer higher-level controllers such as the ATL900 and ATLDPS1.

Who should read it

Electrical designers in Brazil and Latin America selecting complete ATS units for generator and mains transfer.

Document contents

  1. Automatic transfer controllers (product list)
  2. ATL900 controller
  3. ATP enclosed ATS (45-160 A)
  4. ATLDPS1 dual power supply module

Publication details

Authors
LOVATO Electric
Publisher
LOVATO Electric
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

LOVATO Electric LOVATO Electric ATP complete enclosed automatic transfer switches. LOVATO Electric. https://catalogue.lovatoelectric.com/br_pt/Produtos/Controladores-de-transferencia-automatica/CAP31/pc

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.