Logmaster STS V2 60A | 100A | 125A technical product page
Logmaster
Logmaster's STS V2 is a single-phase static transfer switch rated 60, 100 and 125 A, aiming at secure transfer with negligible transfer time even when the two inputs are out of phase.
On this page
Overview
Logmaster's STS V2 is a single-phase, wall-mounted transfer switch using static switching technology. The manufacturer says it was developed to provide secure, imperceptible energy transfer even when the two inputs are out of phase, and to give negligible transfer time for any type of load. Three discrete single-phase current ratings are published: 60, 100 and 125 A.
Features include 220/120 V (factory set) voltage, a backlit liquid crystal display, terminal-block and NBR 14136 20 A socket outputs, input breakers for Source A and Source B, an event log in non-volatile memory and an auxiliary 20 A socket with redundancy. Priority input selection is manual or through LogBlueWeb software.
Optional hardware is a preventive maintenance schedule, a USB-C communication interface, a dry-contact interface and an EPO (emergency power off) function. The page gives no numeric transfer time, synchronisation window or short-circuit withstand; the manual and catalogue are downloadable for detail. Because three ratings are published on one page, the conditions of each configuration should be kept separate.
Key points
- Three discrete single-phase ratings: 60, 100 and 125 A.
- Static switching; secure transfer is aimed at even with a phase difference between sources.
- Voltage 220/120 V, set at the factory.
- Backlit LCD; event log in non-volatile memory.
- Separate input breakers for Source A and Source B.
- Priority input selected manually or with LogBlueWeb software.
- Output: terminal block and NBR 14136 20 A socket; auxiliary 20 A socket with redundancy.
- Optional: preventive maintenance schedule, USB-C, dry contact, EPO.
Using it in design
- For dual-source supplies (for example two UPS outputs), consider the STS rather than an ATS for single-phase loads that need seamless transfer.
- Select the current rating (60, 100, 125 A) above the load current and confirm the single-phase limit.
- Check coordination of the separate Source A and B input protection with their own breakers.
- Write the USB-C, dry-contact and LogBlueWeb options into the order specification according to monitoring needs.
- Take numeric transfer time and synchronisation window values from the catalogue.
Who should read it
Electrical designers selecting an STS for single-phase critical loads fed from two sources.
Document contents
- Product description
- Features and options
- Downloads (manual, catalogue)
Publication details
- Authors
- Logmaster
- Publisher
- Logmaster
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Logmaster Logmaster STS V2 60A | 100A | 125A technical product page. Logmaster. https://logmaster.com.br/produtos/chave-de-transferencia-automatica-sts-v2/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.