Technical guideFree to readYear not stated

Logmaster ATS 60 | 80 | 100 | 140 A technical product page

Logmaster

Logmaster's single-phase, wall-mounted ATS range switches automatically between generator, UPS and mains at 60, 80, 100 and 140 A, with a 220/120 V voltage selector switch.

On this page

Overview

Logmaster's product page presents a compact automatic transfer switch (ATS) for medium-power redundant energy systems: four discrete single-phase, wall-mounted current options of 60, 80, 100 and 140 A. The manufacturer says the device is designed with fully domestic technology and suits installations that combine a generator, a UPS and the mains.

The technical information on the page is limited: voltage is 220/120 V set with a voltage selector switch, a panel gives visual indication, and output connections are a terminal-block type and a 20 A socket to NBR 14136. The page gives no per-rating transfer time, contact type, short-circuit withstand or dimensions; these are in the downloadable manual and catalogue.

Because the four current ratings are published together on one product page, the published conditions and unknown fields of each configuration should be kept separate during selection. The page is a product introduction and contains no test data.

Key points

  1. Four discrete current options: 60, 80, 100 and 140 A, single-phase.
  2. Wall mounting.
  3. Voltage 220/120 V with a voltage selector switch.
  4. Recommended for installations combining generator, UPS and mains.
  5. Panel with visual indication.
  6. Output connection: terminal block and NBR 14136 20 A socket.
  7. The manufacturer states the product uses fully domestic technology.
  8. Manual and catalogue are downloadable; the page gives no per-rating transfer time.

Using it in design

  • Match the load current to the 60, 80, 100 or 140 A rating with a margin and confirm the single-phase limit.
  • Set the selector switch to the site voltage (220 V or 120 V).
  • Take missing data such as transfer time and contact type from the downloadable catalogue and carry it into the specification.
  • Match the output connection (terminal block or NBR 14136 20 A socket) to the load side.
  • If sensitive IT load needs seamless transfer, consider a static transfer switch (STS) instead of an ATS.

Who should read it

Electrical designers and installers selecting ATS for small and medium single-phase redundant supplies.

Document contents

  1. Product description
  2. Features
  3. Downloads (manual, catalogue)

Publication details

Authors
Logmaster
Publisher
Logmaster
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Logmaster Logmaster ATS 60 | 80 | 100 | 140 A technical product page. Logmaster. https://logmaster.com.br/produtos/chave-de-transferencia-automatica-ats-60-80-100-140a/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.