JUTRION JUQ5 PC Class Automatic Transfer Switch technical specifications
JUTRION
JUTRION's JUQ5 product page describes a PC-class automatic transfer switch to IEC 60947-6-1 in eight frames from 16 A to 800 A: AC 230/400 V, 2, 3 or 4 poles, utilisation category AC-33iB and a total transfer time of at most 1.3 seconds.
On this page
Overview
The page presents the JUQ5 series PC-class automatic transfer switch from Chinese manufacturer JUTRION. The product is designed for AC 50/60 Hz, AC 400 V systems and rated currents up to 800 A. It transfers the load automatically from the normal to the standby source on a power failure, undervoltage, overvoltage or phase loss. It supports automatic and manual operation, has I-0-II positions and is mechanically interlocked. The manufacturer stresses that the transfer does not rely on a circuit-breaker mechanism but on a dedicated PC-class transfer mechanism.
The specification table gives the rated operational voltage as AC 230 V / 400 V, frequency as 50/60 Hz, insulation voltage as AC 690 V and impulse withstand voltage as 8 kV. The utilisation category is AC-33iB. Total transfer time is 1.3 seconds or less and contact transfer time 0.6 seconds or less. The switch has an isolation function, front connection and fixed vertical mounting. Degree of protection is IP20, ambient operating temperature is -5 °C to +40 °C and the altitude limit is 2000 m.
The model table lists eight frames with their discrete current ratings: JUQ5-63 (16-63 A), JUQ5-80 (63 and 80 A), JUQ5-125 (63-125 A), JUQ5-225 (100-225 A), JUQ5-250 (100-250 A), JUQ5-400 (250-400 A), JUQ5-630 (400-630 A) and JUQ5-800 (630-800 A). The page notes that specifications can vary with frame size, pole configuration and controller type. Short-circuit withstand values are not on the page; the applications listed include commercial buildings, industrial facilities, generator backup systems, data centres and hospitals.
Key points
- PC-class automatic transfer switch; standard IEC 60947-6-1; utilisation category AC-33iB.
- Rated current 16-800 A; 2, 3 or 4 poles; Ue AC 230 V / 400 V; 50/60 Hz.
- Ui AC 690 V; Uimp 8 kV.
- Total transfer time 1.3 s or less; contact transfer time 0.6 s or less.
- Frames and currents: JUQ5-63 16, 20, 25, 32, 40, 50, 63 A; JUQ5-80 63, 80 A; JUQ5-125 63, 80, 100, 125 A; JUQ5-225 100, 125, 160, 180, 200, 225 A.
- JUQ5-250 100-250 A (seven steps); JUQ5-400 250, 315, 350, 400 A; JUQ5-630 400, 500, 630 A; JUQ5-800 630, 700, 800 A.
- Three positions I-0-II, mechanical interlock and isolation function; front connection, fixed vertical mounting.
- IP20; operating temperature -5 °C to +40 °C; altitude up to 2000 m.
Using it in design
- With a transfer time of up to 1.3 seconds, use the switch at the UPS input, for generator transfer or on mechanical-load boards; IT load must be carried by the UPS during the changeover.
- The same current appears in more than one frame (63 A is in JUQ5-63, JUQ5-80 and JUQ5-125), so choose the frame by panel layout and the likelihood of a later current increase.
- A PC-class switch does not clear fault current; obtain the conditional short-circuit and short-time withstand values from the manufacturer and coordinate them with the upstream protective device.
- Choose the 2-pole version for single-phase circuits and the 4-pole version for three-phase systems where the neutral has to be switched.
- For panel temperatures above 40 °C or sites above 2000 m, request derating values from the manufacturer.
Who should read it
Electrical engineers designing low-voltage transfer boards, panel builders and generator integrators.
Document contents
- Key Features of the JUQ5 PC Class Automatic Transfer Switch
- JUQ5 Component Overview
- Technical Specifications
- Model and rated current table
- Applications
- Compliance & Standards
- Why Choose JUTRION JUQ5 ATS?
Publication details
- Authors
- JUTRION
- Publisher
- JUTRION
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
JUTRION JUTRION JUQ5 PC Class Automatic Transfer Switch technical specifications. JUTRION. https://jutrion.com/products/juq5-pc-class-automatic-transfer-switch
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.