Shinhoo AWZ65-40-160 Horizontal Single Stage Pump
Original title Shinhoo: AWZ65-40-160 technical data
Shinhoo
Shinhoo AWZ65-40-160 is a DN65, 380 V / 50 Hz, 4 kW horizontal single-stage wet-rotor pump; the page lists a maximum flow of 40 m³/h and a maximum head of 37.5 m.
On this page
Overview
The page presents Shinhoo's AWZ65-40-160 horizontal single-stage pump. It works on a wet-rotor system, with hydraulics designed using a 3D impeller and hydraulic simulation and a custom high-efficiency motor. Communication is PWM, protection class IP55 and the connection type is chuck.
The technical table lists DN 65 mm, rated flow 25 m³/h, rated head 40 m, maximum head 37.5 m, 380 V, 50 Hz, 4,000 W and a port-to-port length of 557 mm. The header gives maximum flow as 40 m³/h. The rated and maximum head values appear inverted in the table, so selection should rest on the performance curve.
Operating conditions are medium temperature -25 to +110 °C, operating ambient -25 to +55 °C and storage -35 to +60 °C (with no freezing in pipe or pump). Application fields listed are charging-station liquid cooling, storage liquid cooling, domestic water supply, hot water circulation and HVAC, and industrial circulation.
A performance-curves tab exists, but no numerical curve data appears as text. The pump may be a candidate for circulation in data-centre cooling water loops; before selection, the curve, NPSH and fluid compatibility should be confirmed with manufacturer data.
Key points
- DN 65, 380 V, 50 Hz, 4,000 W, IP55, port-to-port length 557 mm.
- Header: maximum flow 40 m³/h and maximum head 37.5 m; table: rated flow 25 m³/h and rated head 40 m.
- Medium temperature -25 to +110 °C; operating ambient -25 to +55 °C; storage -35 to +60 °C.
- Wet-rotor system, 3D impeller design and hydraulic simulation.
- PWM communication interface; chuck-type connection.
- Application fields: liquid-cooled charging and storage systems, domestic water, hot water circulation and HVAC, industrial circulation.
Using it in design
- Compare the performance curve with the duty point rather than relying on the table's rated and maximum head values.
- With a medium range of -25 to +110 °C, ask the manufacturer about viscosity effects in glycol cooling loops.
- Add the 380 V / 50 Hz, 4 kW supply and IP55 protection to the electrical design.
- If pump redundancy is needed, plan an N+1 arrangement and size the common header from the DN65 connections.
Who should read it
Mechanical designers selecting pumps for cooling water loops.
Document contents
- Technical data
- Application fields
- Features and benefits
- Performance curves
Publication details
- Authors
- Shinhoo
- Publisher
- Shinhoo
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Shinhoo Shinhoo: AWZ65-40-160 technical data. Shinhoo. https://www.shinhoopump.com/awz65-40-160-horizontal-single-stage-pump_p596.html
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.