CST HDFS263-0094 Dry Cooler Repeat Order: Catalogue Specifications
CST (VRCOOLERTECH)
CST (VRCOOLERTECH) lists the HDFS263-0094 dry cooler at 94 kW with 34% ethylene glycol, 17.6 m³/h flow and 114 kPa pressure drop; a single-model reference, not a site selection.
On this page
Overview
The document is a CST news page announcing a repeat-order project. An existing customer picked one HDFS263-0094 dry cooler from the standard catalogue, and production and delivery preparation are complete. The page argues that selecting from a standard catalogue shortens model confirmation, technical communication and order execution.
The technical substance is the model's catalogue reference table. The unit rejects 94 kW under a 34% ethylene glycol operating condition. Fluid flow is 17.6 m³/h, fluid-side pressure drop 114 kPa, heat transfer area 198 m², internal volume 26.0 L and air flow 33,113 m³/h. Sound pressure is 61 dB(A) at 10 m, the fan arrangement is 2 × Ø630, the connection DN50 and the reference weight 422 kg.
The table gives no entering or leaving fluid temperatures and no ambient dry-bulb temperature. The text itself states that the values are catalogue references for the stated condition and that final performance, materials, accessories and configuration must be confirmed against project technical documents and the customer-approved selection data.
A dry cooler uses ambient air to cool a circulating fluid and suits closed-loop heat rejection and low water consumption. Because this page illustrates one small 94 kW unit, it gives an order of magnitude for modular dry cooler sizing in data-centre water loops, but it does not replace a design calculation.
Key points
- Model HDFS263-0094: 94 kW heat rejection at 34% ethylene glycol.
- Fluid flow 17.6 m³/h; fluid-side pressure drop 114 kPa.
- Heat transfer area 198 m², internal volume 26.0 L.
- Air flow 33,113 m³/h; fan arrangement 2 × Ø630.
- Sound pressure level 61 dB(A) at 10 m.
- Connection DN50, reference weight 422 kg, quantity 1 unit.
- No fluid or air temperatures are given, so the values do not support direct site selection.
Using it in design
- Use the 34% glycol concentration, with its density and viscosity effect, in pump head calculations, and confirm the temperature at which the 114 kPa figure applies.
- Have the catalogue capacity recalculated at the design ambient temperature and real entering and leaving fluid temperatures; the catalogue reference point is not a site condition.
- Compare 61 dB(A) at 10 m with the site noise limit and the distance to the property boundary.
- Multiply the 422 kg weight and 198 m² surface by the module count when checking structural loads and air-flow clearances.
Who should read it
Mechanical designers doing preliminary dry cooler sizing for data-centre water loops.
Document contents
- Fast repeat selection based on the standard catalogue
- HDFS263-0094 dry cooler catalogue specifications
- Product and service continuity for repeat orders
- About CST (VRCOOLERTECH)
Publication details
- Authors
- CST (VRCOOLERTECH)
- Publisher
- CST (VRCOOLERTECH)
- Year
- 2026
- Document language
- Unverified
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
CST (VRCOOLERTECH) (2026). CST HDFS263-0094 Dry Cooler Repeat Order: Catalogue Specifications. CST (VRCOOLERTECH). https://www.cstheatexchanger.com/Dry-Cooler-Repeat-Order-Project-Model-Selected-Based-on-Standard-Catalog-id08874935.html
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.