Technical guideFree to readYear not stated

DAV. Dry: Fin-Fan Dry Cooler

Dav Coil

Dav Coil's DAV Dry brochure lists tube and fin geometries (S39-S98, Q39-Q98, P30-P60), materials and casing options for custom-designed fan-driven dry coolers; it has no capacity table.

On this page

Overview

The brochure presents the DAV Dry family of packaged heat exchangers that cool industrial fluids in a closed circuit with air. The maker says the high efficiency of the finned surface keeps overall size and installed fan power small. Compared with copper-aluminium exchangers it uses stainless steel tubes and aluminium-alloy fins, which suits aggressive environments. A round-tube, spiral-fin version allows very high internal pressure applications (superheated water, oil) and high-pressure water cleaning.

The geometry tables cover two types. Type A (spiral fin tube) has triangular-pitch types S39, S51, S68, S45, S57, S78, S98 and square-pitch types Q39, Q51, Q68, Q45, Q57, Q78, Q98; pitch S1 is 39-98 mm and tube diameter D is 36, 41 or 51 mm. Type B (round tube, plate fin) has P30, P40, P60 with GT 30, 40, 60 mm and GR 30, 35, 30 mm and 16 mm tube diameter.

Options include threaded, flanged or plain-end brazing connections; casing without casing, side plates only, complete, air-tight or removable cartridge; casing materials carbon steel, galvanised, stainless or aluminium; coatings Blygold, Heresite, cataphoresis or powder paint; droplet separator, humidifier and defrost heaters; one or more fans (EC and Atex Ex included). Typical uses are HVAC, industrial processes and cogeneration. The document gives no capacity, pressure drop or data-centre-specific selection data.

Key points

  1. Type A spiral fin tube: triangular S39, S51, S68, S45, S57, S78, S98; square Q39-Q98.
  2. Type A pitch S1 39-98 mm; tube outside diameter D 36, 41 or 51 mm.
  3. Type B round tube plate fin: P30, P40, P60; GT 30/40/60 mm, GR 30/35/30 mm, d 16 mm.
  4. Stainless steel tubes, aluminium-alloy fins; suitable for aggressive environments.
  5. Casing: none, side plates, complete, air-tight, removable cartridge.
  6. Coatings: Blygold, Heresite, cataphoresis, powder paint.
  7. Fan options: one or more, EC and Atex Ex.

Using it in design

  • Choose the geometry type (tube pitch, fin type) with the manufacturer from summer design air temperature and required capacity; the brochure has no capacity curve.
  • In coastal or dirty environments write the suitable coating (Blygold, Heresite) and casing material into the specification.
  • Use the EC fan option to cut fan power at part load and include it in the free-cooling energy calculation.
  • For high-pressure or glycol circuits confirm tube material and test pressure with the maker.

Who should read it

Mechanical designers specifying custom dry coolers and engineers writing heat-rejection equipment specifications.

Document contents

  1. About the Dry family
  2. Description and advantages
  3. Geometries: Type A spiral fin tube
  4. Geometries: Type B round tube plate fin
  5. Options
  6. Applications

Publication details

Authors
Dav Coil
Publisher
Dav Coil
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Dav Coil DAV. Dry: Fin-Fan Dry Cooler. Dav Coil. https://davcoil.com/wp-content/uploads/2021/11/DAV-Dry_ENG.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.