Technical guideFree to read2025

Frigabohn International Refrigeration Catalogue 2025: FC/FI Neostar Dry Coolers and the Selection Boundary

Original title Friga-Bohn 2025 Catalogue: FC/FI Neostar Dry Coolers

Friga-Bohn

Frigabohn's 2025 catalogue lists FC/FI Neostar axial-fan dry coolers from 20 to 1200 kW with over 5,300 possible models; it gives no selection method and defers to software.

On this page

Overview

Frigabohn's 270-page 2025 International Refrigeration Catalogue covers commercial and industrial refrigeration: under-counter, ceiling and cubic unit coolers, axial-fan condensers, gas coolers, dry coolers, monoblocks and split systems. It opens by promoting a selection software that lets users choose products independently.

For data-centre work the relevant section is the FC Neostar and FI Neostar dry cooler family (20-1200 kW). There are four versions: FC combines compactness with high efficiency, FI offers low pressure drop up to 1,200 kW, and FCR and FIR are forced-draft versions that give low noise and allow EC motors in high-temperature applications. Fin spacing is 1.9 mm for FC and 2.12 mm for FI.

Fan options include a standard two-speed 400 V/3/50 Hz motor, a high-temperature motor and an EC motor with speed variation. The model code defines fin type, motor type, power class (Power or Silence), poles, coupling, fan arrangement and module type. The table lists fan diameters of Ø 800-960 mm, speeds from 250 to 1,200 rpm, motor power from 330 to 3,500 W and sound pressure from 48 to 90 dB(A).

The publication says dry cooler performance varies considerably with operating conditions and therefore presents no selection method in the document; exact thermal duty needs the manufacturer's software. The catalogue gives only correction coefficients: altitude (C1 = 1 - 0.000075 x H), DTM (1 at 15 K), ambient temperature and fluid coefficients, and sound corrections by fan count and distance.

Key points

  1. FC/FI Neostar dry cooler: 20-1200 kW, over 5,300 possible models.
  2. Four versions: FC (compact), FI (low pressure drop, up to 1,200 kW), FCR and FIR (forced draft, low noise).
  3. Fin spacing is 1.9 mm for FC and 2.12 mm for FI.
  4. Fan options: standard two-speed AC, high-temperature AC (H) and EC motor.
  5. Fan diameters Ø 800-960 mm; motor power 330-3,500 W; sound pressure 48-90 dB(A) (EC motors list two operating points).
  6. Altitude coefficient C1 = 1 - 0.000075 x H (H in metres).
  7. DTM coefficient C2: 0.53 at 8 K, 1.00 at 15 K, 1.20 at 18 K.
  8. Sound correction: 2 fans +3 dB(A), 4 fans +6, 8 fans +9, 12 fans +11; reference 10 m, +6 at 5 m, -10 at 32 m.
  9. The fluid freezing point must be at least 5 K below the minimum winter ambient temperature.

Using it in design

  • Determine dry cooler capacity only with the manufacturer's software; the catalogue's correction coefficients are for approximate checks, not full selection.
  • At high-altitude sites apply the C1 altitude coefficient to capacity.
  • Set glycol content so the freezing point stays at least 5 K below minimum winter temperature.
  • Correct sound pressure for fan count and observer distance, and state in the specification that sound power is the contractually binding value.
  • For AC motors with frequent starts (over 30 per hour) or speed drives, consider the thermistor protection option.
  • Where variable speed and low noise are needed, evaluate the EC-motor Silence version.

Who should read it

Mechanical designers selecting dry coolers and condensers for data-centre and industrial plant cooling.

Document contents

  1. Who are we
  2. A world of applications
  3. Regulations and certifications
  4. Cooler and condenser selection coefficients
  5. Unit coolers
  6. Condensers
  7. Gas coolers
  8. Dry coolers (FC NEOSTAR)
  9. Monoblocks and split systems

Publication details

Authors
Friga-Bohn
Publisher
Friga-Bohn
Year
2025
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Friga-Bohn (2025). Friga-Bohn 2025 Catalogue: FC/FI Neostar Dry Coolers. Friga-Bohn. https://frigabohn.com/dA/d9c626fd08/6-EN-INT-2025-%20FRIGABOHN.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.