GAVE CA022002 enclosed automatic transfer product data
GAVE
GAVE's CA022002 product page identifies an enclosed automatic transfer unit with signalling, 2 poles and 25 A; it is declared to IEC 61439-2 and its transfer type is R-G (mains to generator).
On this page
Overview
The page documents one order code in the CA automatic transfer series from GAVE, a Spanish manufacturer of low-voltage electrical material. CA022002 is an enclosed automatic transfer unit with signalling, two poles and a 25 A rating. The manufacturer code is 007CA022002, the EAN is 8430892214032 and the customs code is 85371098. Those identifiers are enough to name the product unambiguously in a purchase list or a bill of materials.
The technical data block has two rows. The standard is IEC 61439-2, which means the product is declared as a low-voltage power switchgear assembly and not as a bare switching device. The transfer type is R-G: the unit is built to change over between one mains source and one generator source. A CE certificate and two instruction files (ND007021 and 5200614-2) are offered as downloads on the page.
The page carries no rated voltage, short-circuit withstand, transfer time, degree of protection or enclosure dimensions; those values sit in the linked instruction files. The same series is sold in 32, 40, 63, 100 and 125 A steps, and in four-pole and surge-protected versions, each under its own code. The 25 A two-pole version is the smallest step in the series, aimed at automatic transfer of small single-phase loads between mains and a generator.
Key points
- Product description: enclosed automatic transfer with signalling, 2 poles, 25 A.
- Manufacturer code 007CA022002, catalogue code CA022002, EAN 8430892214032.
- Declared standard IEC 61439-2 (low-voltage power switchgear and controlgear assemblies).
- Transfer type R-G: changeover between mains and generator.
- Customs code 85371098.
- The page offers a CE certificate and two instruction files (ND007021, 5200614-2).
Using it in design
- Use it for mains-to-generator transfer of single-phase auxiliary loads up to 25 A (a monitoring panel or a small cooling control circuit); move to the four-pole CA024 codes for three-phase loads.
- Match the IEC 61439-2 declaration against the design-verification clauses of the panel specification and take the short-circuit withstand value from the manufacturer's instruction file.
- Because the transfer type is R-G, place the unit between mains and a generator, not between two utility feeds.
- Write code 007CA022002 and the EAN on the bill of materials so the unit is not confused with the surge-protected CA022002P.
Who should read it
Electrical designers selecting small automatic transfer panels, and procurement teams.
Document contents
- Product Information
- Logistic Data
- Technical data
- CE certificate
- Instructions
Publication details
- Authors
- GAVE
- Publisher
- GAVE
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
GAVE GAVE CA022002 enclosed automatic transfer product data. GAVE. https://www.gave.com/en/products/ca-automatic-transfers-413/007CA022002-20477
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.