Technical guideFree to readYear not stated

GAVE motorised changeover and enclosed CA automatic transfers

GAVE

GAVE's motorised changeover and ATS product index lists 170 product codes; the enclosed CA automatic transfers are offered as 2-pole CA022 and 4-pole CA024 codes from 25 A to 125 A, each with a surge-protected version marked by a P suffix.

On this page

Overview

The page is the product index for the motorised changeover and automatic transfer category of the Spanish manufacturer GAVE. The manufacturer states that its motorised changeover switches are designed for remote changeover operations and for electromechanical reliability. The category holds 170 results spread over five pages, with 18 products on the first. Its sub-groups are the D1 series (up to 63 A), the D2/D3 series (up to 250 A), CA automatic transfers and CT automatic transfers with a controller.

The first index page is taken up entirely by enclosed CA automatic transfers with signalling. The code structure is readable: CA022 marks two-pole units, CA024 marks four-pole units, and the last digits give the current step. In the two-pole family CA022002 is 25 A, CA022003 is 32 A, CA022004 is 40 A, CA022006 is 63 A, CA022010 is 100 A and CA022012 is 125 A. In the four-pole family the first page shows the 25, 32 and 40 A steps (CA024002, CA024003, CA024004).

Every current step has a twin with a P suffix, which adds surge protection to the same unit (for example CA022002P and CA024004P). The index gives only a code and a short description; rated voltage, short-circuit withstand and transfer time sit on each code's own product page and in its instruction files. The page therefore works as a starting point for reaching the right order code, not as a selection table.

Key points

  1. The category holds 170 product codes; 18 are listed on the first page.
  2. CA022: 2-pole enclosed automatic transfer; steps of 25, 32, 40, 63, 100 and 125 A.
  3. CA024: 4-pole enclosed automatic transfer; 25, 32 and 40 A steps on the first page.
  4. The P suffix marks the surge-protected version (such as CA022002P, CA022012P, CA024004P).
  5. All CA units have signalling and are supplied enclosed.
  6. Sub-groups: D1 motorised changeovers up to 63 A, D2/D3 motorised changeovers up to 250 A, CA automatic transfers, CT automatic transfers with controller.

Using it in design

  • Choose the family by the number of phases: CA022 for single-phase circuits, CA024 for three-phase-and-neutral circuits.
  • Pick the current step from the 25-125 A range according to load current and the upstream protective device; above 125 A look at the D2/D3 motorised changeovers up to 250 A.
  • On feeds exposed to lightning or switching surges, prefer the P-suffix version and check that it does not conflict with existing surge-protection coordination.
  • Do not rely on the index for short-circuit withstand or transfer time; attach the instruction file from the chosen code's product page to the project file.

Who should read it

Electrical designers selecting small and medium-current source-transfer equipment, and teams preparing bills of materials.

Document contents

  1. Motorised changeover and ATS
  2. Motorised changeover switches D1 up to 63A
  3. Motorised changeover switches D2/D3 up to 250A
  4. CA Automatic transfers
  5. CT Automatic transfers with controller

Publication details

Authors
GAVE
Publisher
GAVE
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

GAVE GAVE motorised changeover and enclosed CA automatic transfers. GAVE. https://www.gave.com/en/products/motorised-changeover-and-ats-409

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.