Refra Air Heat Exchangers
Refra
September 2018 brochure from Lithuanian maker Refra presenting its air-cooled condenser, dry cooler and gas cooler families, copper-tube and aluminium-fin construction and product-code logic.
On this page
Overview
The document is the 2018-09 air heat exchanger brochure of Lithuania-based Refra. The maker presents a range from simple finned-pack coils to condensers, dry coolers and gas coolers. The shared construction is smooth or inner-grooved copper tube with louvered aluminium fins.
Standard tube diameters are 5.0, 7.9, 9.5 and 12.7 mm, with operating pressure up to 120 bar for transcritical CO2 duty. Fin pitch is 2.1 and 2.5 mm as standard and up to 6.5 mm on request. Fans use AC or EC motors and are ErP 2015 compliant; frames are galvanised powder-coated steel, with stainless steel and aluminium as options.
Condenser series run from small flat units (up to 100 kW) through V-shape units up to 800 kW to large double-fan-row units above 1 MW. Dry coolers come in flat, V, W (modular) and flipped-M frame shapes. Gas coolers use the same frame with 7.94 x 54 mm tubes rated to 120 bar.
The brochure is a product overview; it holds no capacity curves and refers to the maker's selection software. For a data-centre designer its value lies in the dry-cooler geometry options, shipping conditions and the method of reading unit features from the product code.
Key points
- Standard tube diameters 5.0, 7.9, 9.5 and 12.7 mm; operating pressure up to 120 bar (transcritical CO2).
- Fin pitch 2.1 and 2.5 mm as standard, up to 6.5 mm optional; epoxy-coated, hydrophilic aluminium and copper fins are also offered.
- The small condenser series (CMBS) reaches 100 kW, the wide series 800 kW, and large V-shape units over 1 MW.
- Dry coolers come as DMHS/LS, DVHS, DVHD, DWHM (modular W) and DFHD/DFHQ (flipped M) shapes.
- Gas coolers use 7.94 x 54 mm tubes rated to 120 bar; EC fans and epoxy-coated fins are standard.
- All standard units fit a freight container, are pressure tested and ship filled with nitrogen.
- Connections below DN50 are threaded, DN50 and above flanged; coils are tested to PED 2014/68/EU.
- The product code encodes unit purpose, frame shape, series, fan row, fan size (500, 630, 800, 910 mm) and fan motor type.
Using it in design
- When selecting dry coolers, weigh frame shape (flat, V, W, flipped M) against the site footprint and the target energy class.
- In corrosive or coastal environments, specify epoxy-coated or hydrophilic fins plus additional protective coating.
- Choose fin pitch against dust and fouling risk: wider pitch eases cleaning, narrower pitch gives compactness.
- Take capacity from the maker's selection software at nominal conditions, not from the brochure, and verify at the design ambient temperature.
- Consider the modular W-type option of splitting into independent circuits in the redundancy scheme.
Who should read it
Mechanical engineers selecting dry coolers and condensers and data-centre designers planning outdoor equipment layout.
Document contents
- Key Features
- Air Cooled Condensers: Main Series
- Dry Coolers: Main Series
- Gas Coolers
- Evaporators, Air Coolers and Other Heat Exchangers
- Additional Features
- Product Code Encryption
- Finned Pack OEM Coils
- Quality and Customer Service
Publication details
- Authors
- Refra
- Publisher
- Refra
- Year
- 2018
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Refra (2018). Refra Air Heat Exchangers. Refra. https://refra.eu/wp-content/uploads/2021/12/air-heat-exchangers-refrigeration-refra-brochure.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.