Technical guideFree to read2026

SAER Solutions for Data Center: From air cooling to liquid and hybrid systems

Original title SAER Pumps and motors for data centers

SAER

SAER's January 2026 leaflet presents pump series for data centre cooling circuits, including SKD (4,500 m³/h, 210 m, up to 1,200 kW), NCB, L/LD, IR, MK and MG, with IE3-IE5 motor options.

On this page

Overview

The three-page leaflet presents the pump range of Italian manufacturer SAER for data centre cooling and water management (LEA 0269, January 2026). Applications are CRAH air cooling systems, direct-to-chip and immersion liquid cooling, dry coolers, chillers and heat exchangers, high-temperature loops, heat recovery, water treatment and distribution, fire fighting and utility water.

Headline values by series: SKD split-casing pumps up to 4,500 m³/h, 210 m head and 1,200 kW, water temperature -15/+120 °C (special -25/+150 °C); NCB/NCBK end-suction 2,300 m³/h, 129 m, 500 kW, -15/+90 °C; L and LD in-line 800 m³/h, 102 m, 90 kW, -25/+140 °C with most models above MEI 0.7; IR close-coupled 825 m³/h, 129 m, 110 kW; MK multistage 110 m³/h, 394 m, 55 kW; MG stub-shaft 825 m³/h, 129 m, 110 kW. All series are 50/60 Hz and can be mounted horizontally or vertically.

Common features include IE3, IE4 and IE5 efficiency class motors, cast iron, bronze, stainless steel and super duplex material options, motor monitoring and protection, internal and external protective coatings and inverter drive options. The manufacturer says hydraulic and electrical efficiency helps lower energy use, PUE and WUE and that impeller diameters are matched to system needs. High-temperature versions are suggested for return loops, heat recovery and high-temperature liquid cooling.

The document is a product introduction and carries no pump curves or efficiency values.

Key points

  1. SKD split-casing: 4,500 m³/h, 210 m, up to 1,200 kW; -15/+120 °C.
  2. NCB/NCBK end-suction: 2,300 m³/h, 129 m, 500 kW; -15/+90 °C.
  3. L and LD in-line: 800 m³/h, 102 m, 90 kW; -25/+140 °C; most models MEI above 0.7.
  4. IR close-coupled: 825 m³/h, 129 m, 110 kW.
  5. MK multistage: 110 m³/h, 394 m, 55 kW; compact vertical.
  6. MG stub-shaft: 825 m³/h, 129 m, 110 kW.
  7. Motor options IE3, IE4 and IE5; materials cast iron, bronze, stainless steel, super duplex.
  8. Horizontal or vertical mounting; 50/60 Hz.
  9. Applications: CRAH, direct-to-chip and immersion, dry coolers, chillers, heat recovery, water treatment, fire fighting.

Using it in design

  • When selecting a pump, verify the operating point on the pump curve rather than the maximum flow and head; the leaflet gives only maximum values.
  • For dry cooler and high-temperature liquid cooling loops, match the temperature limits (-15/+90 to +140/+150 °C) with operating temperature and glycol content.
  • Define the IE3-IE5 motor class and the inverter option together with the variable-flow chilled water control strategy.
  • In space-limited rooms use vertical mounting options (NCB, IR, MG, MK) to cut pump room footprint.
  • Tie material and coating options to the water quality specification for corrosive or treated water circuits.

Who should read it

Mechanical designers selecting pumps for data centre cooling and water circuits.

Document contents

  1. Split casing pumps (SKD)
  2. End suction pumps (NCB/NCBK)
  3. In-line pumps single and twin head (L and LD)
  4. Close coupled pumps (IR)
  5. Multistage pumps (MK)
  6. Stub shaft pumps (MG)
  7. Applications
  8. Featuring

Publication details

Authors
SAER
Publisher
SAER
Year
2026
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

SAER (2026). SAER Pumps and motors for data centers. SAER. https://saerelettropompe.com/images/download-area/documenti-sito/LEA-Leaflet/LEA_0269_2026.01_Data-center_EN_00.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.