Industrial cooling towers / Packaged cooling towers (Seagull)
Original title Industrial cooling towers / Packaged cooling towers
Seagull
Seagull is a manufacturer source separating custom field-built industrial cooling towers from factory-made packaged towers and closed-circuit options; the maker holds more than 100 patents.
On this page
Overview
Seagull Cooling Tower describes industrial cooling towers as towers designed for the application, shipped from the manufacturer's works with materials and custom-manufactured components. Packaged cooling towers are pre-fabricated modular towers delivered as a complete unit and only installed on site.
The product families are crossflow and counterflow wet towers (in reinforced concrete, FRP or hot-dip galvanised steel) and closed-circuit towers. A closed circuit tower is an evaporative cooler that absorbs the heat of the cooled fluid through evaporation of spray water outside the coil. Innovation topics are plume abatement, super low noise, high-level water collection and intelligent control; parts include fill, spray nozzle, drift eliminator, fan stack and drive shaft.
On the page the manufacturer states it holds more than 100 invention patents and serves industries such as power, petrochemical, pulp and paper, sugar, mining and metals. Project references include 32 NHS-4900 towers (a coal-fired power plant in Bangladesh).
Key points
- Industrial towers are designed for the application and shipped from the manufacturer's works with custom-manufactured components.
- Packaged towers are pre-fabricated modular units installed on site.
- Wet tower types are crossflow and counterflow; structure is reinforced concrete, FRP or hot-dip galvanised steel.
- A closed circuit tower takes heat from the cooled fluid by evaporation of spray water outside the coil.
- The manufacturer states it holds more than 100 patents.
Using it in design
- Choose between a custom field-built tower and a packaged modular tower on commissioning time and expansion flexibility for the data centre.
- Consider a closed circuit tower where keeping the condenser water loop clean justifies the heat transfer and water quality trade-off.
- Set the tower structure material (FRP, galvanised steel, reinforced concrete) by site environment and service life.
- Write plume abatement and low-noise options into the specification according to local constraints.
Who should read it
Mechanical designers choosing cooling tower architecture for a data-centre condenser water system.
Publication details
- Authors
- Seagull
- Publisher
- Seagull
- Year
- Year not stated
- Document language
- Unverified
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Seagull Industrial cooling towers / Packaged cooling towers. Seagull. https://www.seagull-ct.com/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.