Shakti SCR/SCRI/SCRN Vertical Multistage Pumps: 50 Hz Catalogue (L15, June 2026)

Original title Shakti SCR/SCRI/SCRN 50 Hz catalogue, L15, 4 June 2026

Shakti Pumps

Shakti Pumps' June 2026 catalogue lists SCR, SCRI and SCRN pumps in 14 sizes from 0.8 to 215 m³/h rated flow, 0.37-75 kW motors, 20-40 bar maximum pressure and -20/+120 °C.

On this page

Overview

The document is the 50 Hz catalogue of Shakti Pumps' SCR (cast iron and AISI 304 stainless steel), SCRI (AISI 304) and SCRN (AISI 316) vertical multistage pump series (L15, 4 June 2026). The series has 14 sizes from SCRN 1s to SCRN 215, where the size number indicates rated flow in m³/h (0.8, 1, 3, 5, 10, 15, 20, 32, 45, 64, 90, 125, 155, 215).

The range table gives flow ranges from 0.3-1.1 m³/h up to 108-280 m³/h; maximum pressure 20 to 40 bar, and high pressure on request 39 to 48 bar. Maximum pump efficiency is 35% at the small end and 82% at the large end. Motor power runs from 0.37 to 75 kW. Standard temperature range is -20/+120 °C (-30/+120 °C for some sizes), with -40/+180 °C on request. Pump performance is given to ISO 9906:2012 Grade 3B.

Connection options are DN 25 to DN 200 flanges and 1 1/4" to 8" Victaulic (PJE) couplings. The materials table lists AISI 304 or 316 for pump head, base, impeller, chambers and outer sleeve on SCRI and SCRN, duplex for the shaft, PTFE and carbon graphite for bearings, a cartridge-type mechanical seal and EPDM or FKM O-rings.

The catalogue holds model-by-model flow-head tables (for example SCRI/SCRN 5-2 to 5-36 at flow points from 0 to 8.5 m³/h), motor power and current, mounting dimensions and weights. The tables are catalogue performance data, not a duty point selected for a particular installation, and motor rated power is not measured electrical consumption.

Key points

  1. 14 sizes: rated flow 0.8 to 215 m³/h; the size number indicates flow.
  2. Flow range 0.3-1.1 to 108-280 m³/h; maximum pressure 20 to 40 bar.
  3. High pressure on request 39 to 48 bar.
  4. Maximum pump efficiency 35% (small size) to 82% (large size).
  5. Motor power 0.37 to 75 kW.
  6. Standard temperature range -20/+120 °C; -40/+180 °C on request.
  7. SCR cast iron and AISI 304; SCRI AISI 304; SCRN AISI 316.
  8. Performance to ISO 9906:2012 Grade 3B.
  9. Connections DN 25-DN 200 flanges and 1 1/4"-8" Victaulic couplings.

Using it in design

  • Read the duty point from the model-specific flow-head table; rated flow and maximum values do not stand in for it.
  • Check efficiency by size: small sizes peak at 35-60%; for continuously running loops consider a larger size or a different pump type.
  • Select the material (AISI 304 or 316) from water quality for glycol or treated circuits.
  • Compare temperature limits (-20/+120 °C standard) with glycol content and operating temperature.
  • Do not confuse motor rated power with actual consumption at the selected flow; use duty point power for energy calculations.

Who should read it

Mechanical designers selecting vertical multistage pumps for chilled water, make-up and pressure boosting circuits.

Document contents

  1. Range table (SCR, SCRI, SCRN)
  2. Connections
  3. Material list
  4. Dimension and weight tables
  5. Performance (flow-head) tables

Publication details

Authors
Shakti Pumps
Publisher
Shakti Pumps
Year
2026
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Shakti Pumps (2026). Shakti SCR/SCRI/SCRN 50 Hz catalogue, L15, 4 June 2026. Shakti Pumps. https://shaktipumps.com/wp-content/uploads/2026/06/2000002666.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.