CRAC / CRAHUs: High Performance Cooling Solutions (Silent-Aire)
Original title Computer Room Air Conditioner and Air Handling Unit
Silent-Aire
Silent-Aire's application page for custom-built CRAC/CRAH units: up to 260 tons per cooling mode, 20,000-104,000 CFM airflow, with free cooling, chilled water, DX and evaporative options.
On this page
Overview
The page describes Silent-Aire's CRAC and CRAHU (air handling unit) products used in data centres. Units are presented with heavy-duty construction, full packaging, single-point electrical and water connection, variable-speed operation and an 18 gauge steel casing. The standard filter is MERV13, fans are compact airfoil plenum fans on VFDs, and evaporative pad thickness can be chosen between 4 and 12 inches.
Cooling options come under five headings: free cooling (when outdoor conditions allow, all other cooling is off and only fans run), chilled-water coils fed from the owner's central plant (pressure drop is said to be roughly half that of an equivalent off-the-shelf CRAC), DX (air or water cooled, HFC-based refrigerants), direct/indirect evaporative cooling (up to 95% less energy than traditional cooling) and project-specific methods. In dry climates the whole peak load can be met by direct evaporative cooling alone.
The performance section gives up to 260 tons for each cooling mode and, as standard, 20,000 to 104,000 CFM. Units are downflow as standard, with upflow and horizontal options. Controls are based on CAREL pCO programmable controllers supporting Modbus, LonWorks, BACnet and SNMP. For maintenance, fan and motor inspection every 3-4 months and coil cleaning every 2-3 months are recommended. The page is promotional and states no rating conditions.
Key points
- Capacity up to 260 tons for each cooling mode; standard airflow 20,000-104,000 CFM.
- Downflow is standard; upflow and horizontal configurations are available.
- MERV13 filters, VFD plenum fans, 18 gauge steel casing, evaporative pad 4-12 inches.
- For chilled water, the water pressure drop is said to be roughly half that of an equivalent off-the-shelf CRAC.
- Direct/indirect evaporative cooling needs up to 95% less energy than traditional cooling and works best at high temperature and low to medium humidity.
- When free cooling is engaged all other cooling is off and only the unit fans run.
- Controls are CAREL pCO based and support Modbus, LonWorks, BACnet and SNMP.
- Maintenance intervals: fans and motors every 3-4 months, coil cleaning every 2-3 months, fasteners annually.
Using it in design
- Select the cooling mode by climate: direct evaporative in dry climates, chilled water or DX hybrid in humid ones.
- When sizing chilled-water pumps, verify the manufacturer's pressure-drop claim against the project quotation data.
- For evaporative cooling, add water quality, drainage and maintenance programme to the operations plan.
- State the electrical standard (CEC, NEC, IEC) and control protocol explicitly in the specification.
Who should read it
Mechanical designers reviewing large-scale CRAC/CRAH and evaporative cooling solutions.
Document contents
- General features and uses
- Construction details
- Cooling options
- Performance data
- Controls and operating systems
- Commissioning and maintenance
Publication details
- Authors
- Silent-Aire
- Publisher
- Silent-Aire
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Silent-Aire Computer Room Air Conditioner and Air Handling Unit. Silent-Aire. https://www.silent-aire.com/cracsandcrahu/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.