Smardt AeroPure AF air-cooled chiller: data centre model selection
Original title AeroPure AF Series brochure
Smardt
Smardt AeroPure AF is an air-cooled chiller series with magnetic-bearing oil-free compressors, covering 211-2500 kW (60-710 TR), up to 16.0 EER and a 30-second fast restart.
On this page
Overview
The brochure, published August 2026, presents TICA-Smardt's AeroPure AF series. It builds on oil-free magnetic-bearing compressor technology with over 12,000 installations and spans 60-710 TR (211-2500 kW). Available refrigerants are R134a, R513A, R515B and R1234ze. Target applications are process cooling and data centres as well as comfort cooling.
Key features: low-GWP refrigerant options, up to 16.0 EER (full load) or 25.9 IPLV depending on model and application, compressor operation resuming in as little as 30 seconds after brief power interruptions (reaching 90 % of the pre-outage RPM can take up to 110 seconds in field conditions), a redundant compressor configuration that allows operation with only one compressor, and an operating range of -20 to 130 °F (about -29 to 54 °C). Certifications: AHRI, CE, ETL, ASHRAE 15, MEPS.
Options include a THDI filter, ATS, EC fans with normal and extended external pressure, a double refrigerant circuit, remote access, the Smardt Cool optimisation package, heat-exchanger protective coatings and a low-ambient kit. Units are designed to fit standard 20 ft or 40 ft high-cube containers, simplifying freight and rigging.
The data-centre model mix is given in two refrigerant groups. R134a/R513A models span 315-1425 kW nominal capacity and R1234ze/R515B models 220-1320 kW; examples are AF060.2B.F22.10.S3 at 630 kW (179 TR), AF135.3I.F26.20.S3 at 1425 kW (405 TR), AF050.2P.F26.08.S4 at 520 kW (148 TR) and AF120.3G.F26.20.S4 at 1319 kW (375 TR). Additional models reach 2,500 kW (AF240.4G.F22.40.S4, 711 TR). Some model groups are rated at 52 °C outdoor air with 36 °C entering and 24 °C leaving water, others at 45 °C, 31 °C and 24 °C.
Key points
- Capacity 60-710 TR (211-2500 kW); refrigerant options R134a, R513A, R515B, R1234ze.
- Up to 16.0 EER at full load or 25.9 IPLV (depending on model and application).
- Fast restart: compressor resumes in 30 seconds after a brief interruption; reaching 90 % of RPM can take up to 110 seconds in field conditions.
- Redundant compressor configuration: operation continues with only one compressor running.
- Operating range -20 to 130 °F (about -29 to 54 °C); extended options available.
- Data-centre model mix: 315-1425 kW for R134a/R513A and 220-1320 kW for R1234ze/R515B; largest example 2500 kW (711 TR).
- Example models: AF060.2B.F22.10.S3 630 kW; AF090.2I.F26.14.S3 949 kW; AF135.3I.F26.20.S3 1425 kW.
- Nominal regimes: outdoor 52 °C with water 36-24 °C, and outdoor 45 °C with water 31-24 °C.
- Designed for 20 ft or 40 ft high-cube container shipment.
Using it in design
- When selecting a data-centre chiller, check the outdoor-air and water regime behind nominal capacity (52 °C / 36-24 °C or 45 °C / 31-24 °C) against the site design ambient.
- Compare the recovery time after a short mains interruption (30 to 110 seconds) with the heat-up rate of the critical load; size chilled-water buffer tanks and UPS scope accordingly.
- Include the redundant compressor structure and the double-circuit option in N+1 redundancy calculations.
- Evaluate the low-GWP refrigerants (R513A, R515B, R1234ze) against local F-gas and emissions rules; nominal capacity is lower in the R1234ze and R515B groups.
- Specify the THDI filter and ATS options according to power quality and the backup power architecture.
Who should read it
Mechanical designers and investment decision makers selecting air-cooled chillers for data centres.
Document contents
- About Smardt
- AeroPure AF series
- Fit for data centres and comfort cooling
- Installation advantages
- Key features
- Optional features and configurations
- Model mix (data centre)
- Lifecycle performance and services
Publication details
- Authors
- Smardt
- Publisher
- Smardt
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Smardt AeroPure AF Series brochure. Smardt. https://cdn.sanity.io/files/e1r156ge/production/c23f0704e4e138ec1cc6352d9ccd4bd7439a07b8.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.
