Technical guideFree to read2024

Taco 1900 Series In-Line Pumps catalog, 2024

Original title 1900 Series In-Line Pumps

Taco Comfort Solutions

Taco's May 2024 catalog presents 1900 Series close-coupled in-line pumps: 10 to 250 GPM flow, heads to 160 feet, 175 psi maximum pressure and 300 °F maximum temperature.

On this page

Overview

The document is the 2024 product catalog for Taco Comfort Solutions' 1900 Series close-coupled in-line circulator pumps (catalog 300-1.4, effective 05/15/24). The series has five basic models from 1-1/2 inch x 1-1/2 inch to 2 inch x 2 inch, with flow of 10 to 250 GPM and head to 160 feet. The pumps are designed to be supported by the piping and can be mounted horizontally or vertically.

The catalog lists commercial hydronic applications, air conditioning, cooling towers, recirculation and booster service. The standard mechanical seal is a Type 21 design with a ceramic seat; Sealide C is available for aggressive fluids. The motor is a NEMA 56 frame C-face type, and permanently sealed grease-lubricated bearings keep maintenance low.

Operating specifications: maximum operating pressure 175 psi (125 psi flanges standard), mechanical seal temperature 250 °F standard and 300 °F optional. The casing is cast iron or stainless steel, and the one-piece impeller is cast stainless steel (304); an NSF 61 certified stainless option exists. The catalog also has tables of model, speed (1,760 and 3,500 rpm), flange size, motor power (1/4 to 7.5 HP) and dimensions. It is a general-purpose pump catalog with no data-center-specific design guidance.

Key points

  1. Five basic models from 1-1/2 x 1-1/2 inch to 2 x 2 inch; flow 10 to 250 GPM and head to 160 feet.
  2. Maximum operating pressure 175 psi (125 psi flanges standard); mechanical seal temperature 250 °F standard, 300 °F optional.
  3. NEMA 56 frame C-face motor; speeds of 1,760 and 3,500 rpm; power from 1/4 to 7.5 HP.
  4. Casing in cast iron (stainless fitted) or all stainless steel; NSF 61 certified option.
  5. One-piece enclosed, dynamically balanced cast stainless steel (304) impeller; 416 stainless shaft.
  6. Type 21 mechanical seal, ceramic (standard) or Sealide C; one seal size and one shaft extension fit all models.
  7. 1/4 NPT pressure tappings on suction and discharge allow differential pressure readings; the rear pull-out design allows service without disturbing piping.
  8. Pumps are factory tested and built to Hydraulic Institute standards.

Using it in design

  • For small cooling water or auxiliary hydronic circuits, match the flow (10 to 250 GPM) and head (to 160 feet) range to the circuit and verify the pump curve duty point after converting to SI.
  • On glycol or hot circuits, check the mechanical seal temperature limit (250 °F standard, 300 °F option) and the 175 psi maximum pressure.
  • In duty/standby (N+1) pump arrangements, consider the rear pull-out design and pressure tappings for service access.
  • In cooling tower and recirculation duty, choose casing material (cast iron or stainless) by water quality.
  • The catalog does not describe a data center application; for critical facilities define pump redundancy and motor drive requirements separately.

Who should read it

Mechanical designers and procurement engineers selecting in-line pumps for auxiliary cooling water and hydronic circuits.

Document contents

  1. Features and benefits
  2. Commercial hydronic application information
  3. Operating specifications
  4. Materials of construction
  5. Pump dimensions and weights

Publication details

Authors
Taco Comfort Solutions
Publisher
Taco Comfort Solutions
Year
2024
Document number
300-1.4, effective 2024-05-15
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Taco Comfort Solutions (2024). 1900 Series In-Line Pumps. Taco Comfort Solutions. 300-1.4, effective 2024-05-15. https://tacocomfort.com/documents/FileLibrary/1900Series_Catalog_300-1.4.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.