White paperCitation2012

WP#45 - Data Center Life Cycle Assessment Guidelines

The Green Grid · Christophe Garnier, Mark Aggar et al.

A Green Grid framework for assessing a data centre's complete life cycle across relevant environmental impacts; it focuses on assessment boundaries and environmental concerns and leaves out economic and social aspects.

On this page

Overview

This white paper from The Green Grid is dated 20 November 2012, and its editor is Christophe Garnier (Schneider Electric). It provides a framework for assessing a data centre's complete life cycle across the relevant environmental impacts. Its starting point is that existing life cycle assessment (LCA) tools each have limited and differing scopes and usually give gross estimates at best.

The framework's focus is on defining assessment boundaries and environmental concerns. The document is therefore less about supplying a calculation tool than about clarifying what an LCA study should include and exclude. This approach is necessary if the results of different studies are to be comparable.

The document also states what it leaves out: economic and social aspects, such as conflict materials, are outside the framework. Results should therefore be read as an environmental impact assessment only, not a full sustainability analysis. The record rests only on the abstract on the TGG library page and gives no detail of the document's internal structure.

EN 15978 and ISO 14040/14044 are named as related standards. Being from 2012, the databases and methods used in today's embodied-carbon calculations may be more detailed, yet the principle of defining boundaries remains valid.

Key points

  1. Dated 20 November 2012; editor Christophe Garnier (Schneider Electric).
  2. Existing LCA tools have differing scopes and usually give gross estimates at best.
  3. Provides a framework for assessing a data centre's complete life cycle.
  4. Focuses on assessment boundaries and environmental concerns.
  5. Excludes economic and social aspects such as conflict materials.
  6. Related standards: EN 15978 and ISO 14040/14044.

Using it in design

  • In the embodied-carbon study, define explicit LCA boundaries (modules A-C per EN 15978) and life-cycle stages for the facility and IT.
  • State which stages are included in the lifecycle assessment.
  • Label results as environmental impact only and state that economic and social aspects are excluded.

Who should read it

Sustainability engineers and consultants carrying out data centre carbon and life cycle assessments.

Related standards

  • EN 15978
  • ISO 14040/14044

Publication details

Authors
Christophe Garnier; Mark Aggar; Marc Banks; Jay Dietrich; Bob Shatten; Markus Stutz; Emmanuel Tong-Viet
Publisher
The Green Grid
Year
2012
Document number
WP 45
Document language
English
Source type
Industry body
Access
Citation only
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Download requires a free TGG account sign-in and is governed by The Green Grid Terms of Use; summary and facts from the public library landing page; full text not redistributed.

Citation

Christophe Garnier; Mark Aggar; Marc Banks; Jay Dietrich; Bob Shatten; Markus Stutz; Emmanuel Tong-Viet (2012). WP#45 - Data Center Life Cycle Assessment Guidelines. The Green Grid. WP 45. https://www.thegreengrid.org/en/resources/library-and-tools/236-WP%2345---Data-Center-Life-Cycle-Assessment-Guidelines

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.