White paperCitation2016

WP#71 - Open Standard for Datacenter Availability (OSDA)

The Green Grid · Lex Coors, Rob Bunger et al.

A Green Grid white paper introducing OSDA, an open, non-proprietary availability classification and rating system meant to encourage energy-efficient and sustainable designs.

On this page

Overview

This white paper from The Green Grid is dated 21 December 2016, and its editors are Lex Coors (Interxion) and Rob Bunger (Schneider). It introduces OSDA, the Open Standard for Datacenter Availability. OSDA is an availability classification and rating system designed to encourage energy-efficient and sustainable designs.

The system applies to both new designs and existing facilities and uses availability as its measure of resilience. It is non-proprietary, accepts contributions through TGG members and is a voluntary framework. These features make it an open alternative to classification systems that carry ownership rights.

The document is the first of a series of OSDA framework documents, so the detailed rating rules sit in later documents. The record rests only on the abstract on the TGG library page and contains no class definitions or calculation method.

EN 50600-1 and the Uptime Tier Standard are named as related standards. Because OSDA is voluntary, it creates no legal or contractual obligation; it is an option that designers can use alongside Tier or EN 50600 classes.

Key points

  1. Dated 21 December 2016; editors Lex Coors (Interxion) and Rob Bunger (Schneider).
  2. OSDA is an availability classification and rating system.
  3. Applies to new designs and existing facilities.
  4. Non-proprietary; accepts contributions via TGG members; voluntary framework.
  5. First of a set of OSDA framework documents.
  6. Related standards: EN 50600-1 and the Uptime Tier Standard.

Using it in design

  • Alongside Tier and EN 50600 targets, assess on-site renewables and alternative topologies through availability calculations.
  • Label the rating as a voluntary, open option.
  • State that class definitions must be taken from OSDA's later documents.

Who should read it

Designers choosing a reliability class and owners evaluating energy-efficient, availability-based alternatives.

Related standards

  • EN 50600-1
  • Uptime Tier Standard

Publication details

Authors
Lex Coors; Rob Bunger; Rona Newmark; Lance Rütimann; Roger Tipley; Bob Landstrom
Publisher
The Green Grid
Year
2016
Document number
WP 71
Document language
English
Source type
Industry body
Access
Citation only
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Download requires a free TGG account sign-in and is governed by The Green Grid Terms of Use; summary and facts from the public library landing page; full text not redistributed.

Citation

Lex Coors; Rob Bunger; Rona Newmark; Lance Rütimann; Roger Tipley; Bob Landstrom (2016). WP#71 - Open Standard for Datacenter Availability (OSDA). The Green Grid. WP 71. https://www.thegreengrid.org/en/resources/library-and-tools/433-WP%2371---Open-Standard-For-Datacenter-Availability

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Redundancy scenarios in SoSo CAD

Compare normal operation with equipment failures and see served loads and capacity shortfalls in the same view.

Normal operation and failure scenario comparison in SoSo CAD

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.