Rückkühler (dry cooler configurations)
Original title Rückkühler
thermofin
The thermofin dry cooler page presents seven base series (horizontal, vertical, single and double V, self-draining, power-plant and adiabatic) for water, glycol, deionised water or oil media.
On this page
Overview
German manufacturer thermofin offers its dry coolers across a wide capacity range and says the series were designed for high performance and stability requirements. In-house special solutions allow the units to be fitted into a customer's plant concept. Water, glycol mixtures, deionised water or oil can serve as the cooling medium.
The page lists seven series: horizontal and vertical dry coolers, single-row and double-row V arrangements, a self-draining type, a type for power-plant applications and an adiabatic type. The V arrangement gives high output on limited space and lets units be lined up directly along their long sides. The self-draining series uses an inclined coil block position to drain.
The adiabatic series raises performance by precooling the air. The page names industrial refrigeration, commercial refrigeration, industrial cooling and data-centre cooling as sectors. It carries no exact model capacity table; selection is project specific.
Key points
- Seven series: horizontal, vertical, single-row V, double-row V, self-draining, power-plant and adiabatic dry coolers.
- Media: water, glycol mixtures, deionised water and oil.
- The V arrangement delivers high capacity on limited space and units can be lined up along the long sides.
- The self-draining series drains through an inclined coil block position.
- The adiabatic series boosts capacity by precooling the air.
- Data-centre cooling is named explicitly among target sectors.
- The page contains no model-level capacity values.
Using it in design
- On space-limited roofs and yards, consider V-arrangement units lined up side by side to raise total capacity on one footprint.
- In freezing climates, evaluate glycol concentration together with the self-draining series; capacity must be taken for the actual fluid mixture.
- For hot-weather capacity gaps, compare the adiabatic series against its water consumption and water quality impact.
- Ask the manufacturer for project-specific data on ambient temperature, fluid mixture and approach temperature for each series.
Who should read it
Mechanical designers choosing dry cooler series and arrangement for data-centre and industrial cooling plants.
Document contents
- Rückkühler von thermofin
- Series: horizontal, vertical, V single row, V double row, self-draining, power plant, adiabatic
- Sectors
- Service and downloads
Publication details
- Authors
- thermofin
- Publisher
- thermofin
- Year
- Year not stated
- Document language
- German
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
thermofin Rückkühler. thermofin. https://www.thermofin.de/produkte/rueckkuehler/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.