The Green Grid, 2008, Guide or technical publication
The foundational Green Grid paper that formalised Power Usage Effectiveness (PUE) and its reciprocal, Data Center infrastructure Efficiency (DCiE).
Guide or technical publication
2008
Read at publisher (opens in a new tab)↗
The Green Grid, 2015, Guide or technical publication
A Green Grid white paper that, by analogy with free cooling, aims to use available utility power quality to remove conversion stages and over-provisioned UPS equipment while meeting reliability needs.
Guide or technical publication
2015
Read at publisher (opens in a new tab)↗
The Green Grid, 2015, Guide or technical publication
The Green Grid white paper defining workload archetypes that group typical data centre applications by the useful work they deliver.
Guide or technical publication
2015
Read at publisher (opens in a new tab)↗
The Green Grid, 2015, Guide or technical publication
A Green Grid white paper presenting calculators that estimate energy savings from airflow-management measures such as containment and blanking panels.
Guide or technical publication
2015
Read at publisher (opens in a new tab)↗
The Green Grid, 2017, Guide or technical publication
A Green Grid white paper defining metrics for ICT capacity (the maximum service volume for an investment) and ICT utilization (the share actually used); a framework for looking at useful-work efficie…
Guide or technical publication
2017
Read at publisher (opens in a new tab)↗
The Green Grid, 2017, Guide or technical publication
The Green Grid guidance on finding and removing zombie servers (powered on with little or no productive work), covering cost elements, stakeholders, tools and a detection plan.
Guide or technical publication
2017
Read at publisher (opens in a new tab)↗
The Green Grid, 2017, Guide or technical publication
The Green Grid's 2017 white paper comparing idle-power and SERT-based active-efficiency metrics as regulatory measures of server efficiency.
Guide or technical publication
2017
Read at publisher (opens in a new tab)↗
The Green Grid, 2017, Guide or technical publication
A 2017 Green Grid white paper defining metrics for power demand and energy consumption of compute, storage and network platforms, aligned with WP#72.
Guide or technical publication
2017
Read at publisher (opens in a new tab)↗
The Green Grid, 2021, Guide or technical publication
The Green Grid paper quantifying the gains and costs of CPU P-state and C-state power management.
Guide or technical publication
2021
Read at publisher (opens in a new tab)↗
The Green Grid, 2022, Guide or technical publication
This Green Grid white paper recommends to regulators which criteria and test metrics should be used to assess the power efficiency of online data storage products. It replaces WP#77.
Guide or technical publication
2022
Read at publisher (opens in a new tab)↗
TMMOB Makina Mühendisleri Odası (MMO), 2007, Guide or technical publication
Eser Çizer's TESKON 2007 paper describes 14 years of energy management at Sabancı Center in Istanbul, a mixed office tower that also hosts the Akbank and Sabancı Telekom IT centres.
Guide or technical publication
2007
Read at publisher (opens in a new tab)↗
European Commission JRC, 2025, Guide or technical publication
The 2025 edition of the EU Code of Conduct on Data Centre Energy Efficiency best-practice catalogue, published by the Commission's Joint Research Centre. Numbered practices across management, IT hard…
Guide or technical publication
2025
PDF
Google, 2020, Guide or technical publication
Google's paper on its goal of running on carbon-free energy every hour on every grid by 2030, and why annual 100% renewable matching falls short.
Guide or technical publication
2020
Read at publisher (opens in a new tab)↗
U.S. DOE FEMP / NREL, 2024, Guide or technical publication
A guide written by NREL for U.S. DOE FEMP that updates the 2011 Rumsey Engineers version. It offers practical design principles and setpoints for IT, environmental conditions, air management, cooling…
Guide or technical publication
2024
PDF
BRE Global, 2012, Guide or technical publication
The original standalone BREEAM data centre scheme (issue 1.2, May 2012), since superseded by the NC 2016 data centre annex.
Guide or technical publication
2012
Read at publisher (opens in a new tab)↗
BRE Global, 2019, Guide or technical publication
BRE's data-centre annex, piloted from November 2019 to replace the standalone BREEAM Data Centres 2010 scheme, notable for energy and water disclosure, PUE categories and free-cooling credits.
Guide or technical publication
2019
Read at publisher (opens in a new tab)↗
U.S. DOE FEMP, 2025, Guide or technical publication
A one-page U.S. DOE FEMP fact sheet on the energy efficiency of federal data centers. It quotes headline consumption figures and points to tools, training and guidance at the LBNL Center of Expertise…
Guide or technical publication
2025
PDF
Lawrence Berkeley National Laboratory, 2014, Guide or technical publication
A draft FEMP/LBNL guide and specification for a portable wireless mesh sensor kit that lets an assessor measure air management and estimate PUE in an air-cooled data center without shutting anything…
Guide or technical publication
2014
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2024, Guide or technical publication
An OCP white paper proposing environmental KPIs for data center facilities across energy, greenhouse gases, water, waste and local ecosystem, labelled Required or Recommended for the OCP Ready recogn…
Guide or technical publication
2024
PDF
Lawrence Berkeley National Laboratory (Center of Expertise for Energy Efficiency in Data Centers) / U.S. DOE FEMP, 2020, Guide or technical publication
A catalogue of numbered energy efficiency measures (EEMs) for data centers, maintained by the LBNL Center of Expertise for U.S. DOE FEMP. It gives owners, operators and assessors short rationales…
Guide or technical publication
2020
Read at publisher (opens in a new tab)↗
U.S. DOE Better Buildings / Lawrence Berkeley National Laboratory, 2017, Guide or technical publication
A practical guide written for DOE Better Buildings Challenge partners on metering data centers to measure PUE, focused on The Green Grid's PUE Level 1 (basic). It shows where meters go and how to…
Guide or technical publication
2017
Read at publisher (opens in a new tab)↗
Digital Realty, 2025, Guide or technical publication
Digital Realty's sustainability page gives headline portfolio metrics from its 2025 Impact Report: a portfolio PUE of 1.38 and 93% global renewable electricity coverage. It offers a reference value…
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
Lawrence Berkeley National Laboratory / ANCIS Incorporated, 2023, Guide or technical publication
This 2023 document from LBNL and ANCIS describes the inputs and heat-balance calculations behind the DOE air-management tool. It relates equipment heat, air volume and temperature rise, and explains…
Guide or technical publication
2023
Read at publisher (opens in a new tab)↗
TÜV NORD, Year not stated, Guide or technical publication
TÜV NORD's English-language white paper on the origins, target audience and content of the EN 50600 European standard family and the route to compliance.
Guide or technical publication
-
Read at publisher (opens in a new tab)↗