Key Questions on Energy and AI (World Energy Outlook Special Report)

International Energy Agency, 2026, Guide or technical publication

The IEA's April 2026 follow-up to Energy and AI. It reports data-centre electricity up 17% in 2025 to 485 TWh with 950 TWh projected for 2030, and covers design effects such as rack power density…

Guide or technical publication

2026

PDF

Open Rack Specification V2, Revision 12 (Facebook part number 06-000060)

Open Compute Project Foundation, 2015, Guide or technical publication

Facebook's Open Rack V2 mechanical requirements document (rev 12, July 2015), the predecessor of ORV3. It defines the rack envelope, base and heavy configurations, two power zones, optional kits and…

Guide or technical publication

2015

PDF

Open Rack V3 48V BBU (Battery Backup Unit Module) Specification, Rev 1.4

Open Compute Project Foundation, 2023, Guide or technical publication

The Open Compute Project specification (Rev 1.4, 2023) for the 3 kW lithium-ion battery backup module used in Open Rack V3 BBU shelves. It sets numeric electrical, thermal, mechanical and safety requ…

Guide or technical publication

2023

PDF

Open Rack V3 BBU Shelf Specification, Rev 1.1

Open Compute Project Foundation, 2022, Guide or technical publication

The electrical, mechanical, communications and compliance requirements of the battery backup (BBU) shelf that sits beside the power shelf on the Open Rack V3 48 V busbar (Rev 1.1, 2022). Module-level…

Guide or technical publication

2022

PDF

Open Rack V3 Meta AC WHIP Power Cable, Revision 1.0 (May 2022)

Open Compute Project Foundation, 2022, Guide or technical publication

A Meta-contributed specification for the AC power whip that feeds an ORV3 power shelf directly from the facility's 3-phase WYE supply without a rack PDU. It covers the North American (277/480 VAC…

Guide or technical publication

2022

PDF

Reservoir and Pumping Unit (RPU) Specification, Ver 1.0

Open Compute Project Foundation, 2022, Guide or technical publication

A Meta and CoolIT specification for the rack-mounted reservoir and pumping unit, the control and pumping hub of an air-assisted liquid cooling (AALC) system. It standardizes a way to add liquid-coole…

Guide or technical publication

2022

PDF