Data Centers Heat Reuse 101

Open Compute Project Foundation, 2023, Guide or technical publication

The first white paper of the OCP Heat Reuse sub-project explains why data centre waste heat has so rarely been used, what has changed, and what makes a project viable. It is an introduction to projec…

Guide or technical publication

2023

PDF

Heat Reuse: A Management Primer

Uptime Institute Intelligence, 2023, Guide or technical publication

Uptime Institute Intelligence's Briefing Report 114 summarizes the state of data center waste heat recovery and the drivers for the next few years. The recast EU Energy Efficiency Directive makes…

Guide or technical publication

2023

Read at publisher (opens in a new tab)

NIST SP 800-88 Rev. 2: Guidelines for Media Sanitization

National Institute of Standards and Technology, 2025, Guide or technical publication

NIST's September 2025 guide to setting up an organisational media sanitization programme, so that data on storage media becomes inaccessible before disposal, reuse or loss of control. It bases saniti…

Guide or technical publication

2025

PDF

Plate Heat Exchangers Base Specification, Rev 0 Version 1.0

Open Compute Project Foundation, 2025, Guide or technical publication

The vendor-authored OCP base specification for plate heat exchangers used in data centres (effective 22 August 2025). It sets baseline pressure, material, labelling and documentation requirements…

Guide or technical publication

2025

PDF

Reference Designs for Data Center Heat Reuse, Revision 1.0

Open Compute Project Foundation, 2025, Guide or technical publication

This March 2025 white paper from the OCP Heat Reuse sub-project covers the components, sizing and demarcation point of the heat recovery station for exporting data centre heat, and the options for…

Guide or technical publication

2025

PDF

Energy saving and carbon footprint effect of waste-heat use in data-centre AHU test laboratories (Veri Merkezi Klima Santrali Test Laboratuvarlarında Atık Isının Kullanımı Yöntemiyle Enerji Tasarrufu ve Karbon Ayak İzine Etkisi)

TMMOB Makina Mühendisleri Odası (MMO), 2023, Guide or technical publication

TESKON 2023 paper on the energy and carbon effect of waste-heat recovery in a test laboratory for indirect evaporative cooling (IEC) data-centre air handling units up to 500 kW.

Guide or technical publication

2023

Read at publisher (opens in a new tab)