Water Consumption and Sustainability in Artificial Intelligence Data Centers: Bibliometric Analysis
Original title Yapay Zekâ Veri Merkezlerinde Su Tüketimi ve Sürdürülebilirlik: Bibliyometrik Analiz
Sürdürülebilir Mühendislik Uygulamaları ve Teknolojik Gelişmeler Dergisi · Sema Urnek, Gülser Sayan et al.
An analysis of 51 Web of Science and Scopus publications shows that 86% of the AI data-centre water literature appeared in 2025-2026, with water covered far less than energy.
On this page
Overview
The paper maps the academic literature on the environmental effects of water consumption and energy use in AI data centres using bibliometric methods. A Web of Science and Scopus search for 2015-2026 found 198 records; after removing off-topic and duplicate studies, 51 articles (WoS 39, Scopus 12) were analysed. Inclusion was limited to English-language peer-reviewed articles with accessible full text; theses and conference papers were excluded.
The field is very new: of the 51 publications, 25 appeared in 2025 and 19 in the first three months of 2026, and China is the most productive country. The prominent keywords are data center, AI, energy efficiency and sustainability, while water consumption and water footprint appear less often. The most cited works focus on technical topics such as energy management, green cloud and waste heat recovery.
The discussion sets context with external data the paper reports: citing Lawrence Berkeley National Laboratory, US data centres consumed about 66 billion litres of water directly for cooling alone in 2023 and about 800 billion litres indirectly through electricity generation, and total water consumption could rise two to four times by 2028 with AI-driven expansion.
The authors conclude that studies on direct and indirect water use are limited and that operators reporting AI workloads together with other digital services makes comparison difficult. Recommendations include making WUE a mandatory reporting indicator, annual water footprint in litres/GWh, hybrid cooling and reclaimed water, siting in low-water-stress regions and renewable backup. The work is a literature map; it does not supply site-specific cooling water or energy design inputs.
Key points
- Of 198 records, 51 articles were analysed after removing off-topic studies and duplicates (WoS 39, Scopus 12; 28 duplicate records removed).
- 86% of publications are from 2025-2026: 25 in 2025 and 19 in the first three months of 2026.
- China is the most productive country; the paper notes that Chinese regulation includes WUE as a policy instrument.
- Keywords are weighted to energy and sustainability; water consumption and water footprint appear less frequently.
- Citing IEA, global data-centre electricity use was about 415 TWh in 2024 and is expected to reach about 945 TWh by 2030.
- US data centres consumed about 66 billion litres directly for cooling alone and about 800 billion litres indirectly in 2023 (LBNL, as reported).
- Total water consumption may rise two to four times by 2028 with AI-driven expansion.
- Reporting AI workloads together with other services makes direct calculation of energy, carbon and water footprint difficult.
- Recommendation: WUE should be a standard, mandatory reporting indicator, and annual water footprint should be reported in litres/GWh with direct and indirect components.
Using it in design
- Make water use a decision criterion alongside energy for cooling selection; add WUE and direct plus indirect (electricity-related) water footprint to the table comparing candidate designs.
- In water-stressed regions, prioritise hybrid cooling, air- or seawater-based solutions and reclaimed water at concept design.
- Add regional water stress level and seawater access to the site-selection criteria.
- In backup design, evaluate renewable-based options that reduce diesel generator dependence.
- Build water metering and reporting points (litres/GWh) into the operations monitoring plan from the start.
Who should read it
Researchers working on water use and sustainability policy, AI data-centre planners and regulators.
Document contents
- Introduction
- Literature review
- Material and method (inclusion and exclusion criteria)
- Findings
- Discussion and conclusion
- Recommendations
Publication details
- Authors
- Sema Urnek; Gülser Sayan; Betül Akalın
- Publisher
- Sürdürülebilir Mühendislik Uygulamaları ve Teknolojik Gelişmeler Dergisi
- Year
- 2026
- Document number
- 9(1), 160–171
- Document language
- Turkish
- Source type
- Scientific
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Tam metin yayıncının veya üniversitenin açık kaynağından okundu. Açık erişim, ticari yeniden dağıtım izni olarak yorumlanmadı; yalnızca bağlantı, metadata ve özgün kısa özet tutulur.
Citation
Sema Urnek; Gülser Sayan; Betül Akalın (2026). Yapay Zekâ Veri Merkezlerinde Su Tüketimi ve Sürdürülebilirlik: Bibliyometrik Analiz. Sürdürülebilir Mühendislik Uygulamaları ve Teknolojik Gelişmeler Dergisi. 9(1), 160–171. https://doi.org/10.51764/smutgd.2004236
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.